SECTION 4 — SETUP
4-1 Air Motor Lubricator
WARNING:
The TOUGH GUN Reamer
must be operated with lubricated air
using either the air motor lubricator option or a suitable
alternative system installed by the customer. The lubricator should be set to feed one drop of oil for every 50-75 CFM of air going
through the motor (approximately 1 drop every 5-10 cycles or 1 drop per minute of operation). The lubricant can be air motor oil or
light grade hydraulic oil with a viscosity rating of 150 VC 15-20 (SAE 5W).
4-2 Accessing Electrical and Pneumatic Controls
WARNING:
Ensure power supply is off and disconnected before proceeding. Please follow your facility's lockout / tagout procedures.
To access the electronic circuit board for installation or service for the TOUGH GUN Reamer:
1. Remove reservoir (if equipped) and loosen the two (2) BHCS using a 3 mm Allen wrench to open the hinged rear access door.
2. The rear access door can be completely removed if accessibility is an issue. To do so, using a 3 mm Allen wrench, remove the (3)
BHCS which fasten the hinge to the frame.
OM-TT3-1.4
13