B. Testing Nozzle Detect
1. Move robot into position beside the nozzle detect sensor (with a
nozzle on the torch). The yellow LED should illuminate.
2. Move robot away from the nozzle detect sensor and remove the
nozzle (keeping the retaining head on).
3. Move robot back to the programmed position that was used in
Step 1 above. The yellow light should not illuminate, indicating
that there is no nozzle on the torch.
NOTE:
Adjustments may be necessary if you are not using genuine
Tregaskiss® consumables. The setup distances may change but the
procedure does not change.
Figure 4-F
Figure 4-G
Figure 4-H
OM-TT3-1.4
19