SECTION 6 — INSTALLATION
6-1 Installing the Reamer
WARNING:
Ensure power supply is off and disconnected before proceeding. Please follow your facility's lockout / tagout procedures.
A. To Mount TOUGH GUN TT4A Reamer
The TOUGH GUN Reamer should be installed within the weld cell where it is clear of all tooling and convenient for the robot to access the
unit.
1. Affix the reamer base to a sturdy platform using four (4) M10x1.5x25 mm bolts provided.
Figure 6-A
NOTE:
The reamer can be mounted on an angle (no more than 45°) and can be mounted overhead, only by using the multi-feed adapter kit
(part # TT4-MF-100). Ensure debris falls away from the clamp housing.
12