Start-up
Start-ups
40
07/2019 244156V03_EN
6.2.2
Restart
The machine is restarted after:
each time the machine is switched off/shut down
all maintenance and repair work
whenever the power outlet is replaced on the machine (power outlet re-
placement)
1. Perform a visual inspection during which you check the proper clean-
ing.
2. Check whether all safety covers are in place, properly secured and
without damage.
3. Carry out a function test of the safety switches (
“Functional test of
the safety switches” on page 41).
- The machine is operational.
6.2.3
Start-up after an EMERGENCY STOP
The start-up after
EMERGENCY STOP
is performed after any protective
function of the machine has triggered the EMERGENCY STOP function.
1. The cause for triggering the EMERGENCY STOP function must have
been eliminated. For example if an open cover was the trigger that
must have been closed.
2. Initialise the machine (
“Initialisation” on page 49).
3. Carry out a function test of the safety switches (
“Functional test of
the safety switches” on page 41).
- The machine is operational.
Summary of Contents for PRIMUS 400
Page 2: ......
Page 3: ......
Page 4: ......
Page 7: ......
Page 11: ...Table of contents Table of contents 07 2019 244156V03_EN...
Page 31: ...Safety Safety layout 20 07 2019 244156V03_EN...
Page 43: ...Transport and installation Installation and connection 32 07 2019 244156V03_EN...
Page 57: ...Start up Switch off 46 07 2019 244156V03_EN...
Page 69: ...Operation If a malfunction occurs 58 07 2019 244156V03_EN...
Page 85: ...Visualisation Additional information on the display 74 07 2019 244156V03_EN...
Page 104: ...Maintenance Sharpening the blade 07 2019 244156V03_EN 93...
Page 105: ...Maintenance Sharpening the blade 94 07 2019 244156V03_EN...
Page 109: ...Help and Service If any fault occurs 98 07 2019 244156V03_EN...
Page 116: ...Index 07 2019 244156V03_EN 105 W Workplace lighting 10...
Page 117: ...Index 106 07 2019 244156V03_EN...