Ope
rat
io
n
If a malfunction occurs
07/2019 244156V03_EN
57
Display shows:
ERR 1
Infeed cover not closed
Close the infeed cover
Safety switch is maladjusted or
defective
Call service department.
Display shows:
ERR 2
Front door not locked
Lock front door
Safety switch is maladjusted or
defective
Call service department.
Display shows:
ERR 5
Blade motor overheated
(thermal switch)
Let the motor cool down
Display shows:
ERR 9, 10, 12, 13, 24-26, 32
Controller error
Switch off the machine
Call service department
Display shows:
ERR 11
Knife guard on the machine during
machine operation
Remove knife guard
Display shows:
ERR 16, 33-34
Brake defective
Switch off the machine
Call service department
Display shows:
ERR 23
The measurement object used for
the calibration process is too short
Repeat calibration process with
longer measurement object.
Display shows:
ERR 31
Product feed holder cannot move to
the rear position
Remove product behind the product
feed holder.
The slice thickness is uneven
The product is too soft or too fresh
Let the product stand for a few
hours
Blade is blunt
Replace the blade
The product is not held tight by the
product feed holder
Fasten the product feed holder to
the product
The product feed holder does not
advance
The feed motor is overheated
Let the feed motor cool down
The slices are not clean
Blade is blunt
Replace the blade
The blade's silicone layer is dam-
aged
Replace the blade
The blade cutting edge is smeared
Clean the blade
The following is shown on the dis-
play
A START/STOP button has been
pressed immediately after ending
the cutting process without previ-
ously removing the product.
Open feeding lid, remove product
and close feeding lid.
The following is shown on the dis-
play
The removal chamber has not been
folded up
The removal chamber is not in its
home position
Slice support is blocked
Fold up removal chamber until in
locking position, see page 31
Fold removal chamber down and up
again until in locking position, see
pages 27+31
Remove product residues from
removal chute
Malfunction
Cause
Remedy
Summary of Contents for PRIMUS 400
Page 2: ......
Page 3: ......
Page 4: ......
Page 7: ......
Page 11: ...Table of contents Table of contents 07 2019 244156V03_EN...
Page 31: ...Safety Safety layout 20 07 2019 244156V03_EN...
Page 43: ...Transport and installation Installation and connection 32 07 2019 244156V03_EN...
Page 57: ...Start up Switch off 46 07 2019 244156V03_EN...
Page 69: ...Operation If a malfunction occurs 58 07 2019 244156V03_EN...
Page 85: ...Visualisation Additional information on the display 74 07 2019 244156V03_EN...
Page 104: ...Maintenance Sharpening the blade 07 2019 244156V03_EN 93...
Page 105: ...Maintenance Sharpening the blade 94 07 2019 244156V03_EN...
Page 109: ...Help and Service If any fault occurs 98 07 2019 244156V03_EN...
Page 116: ...Index 07 2019 244156V03_EN 105 W Workplace lighting 10...
Page 117: ...Index 106 07 2019 244156V03_EN...