RECOMMENDED PARTS AND FAULT FINDING
Machine Storage
Remove the filter and clean it, replace with fresh ENDLESSBAG section and store the vacuum cleaner in a place
protected against condensation and at a temperature between 0°C and 40°C.
Cover with a nylon sheet to prevent accumulation of dust.
Scrapping
In case of scrapping, all the component parts of the vacuum cleaner will have to be disposed of through adequate
disposal channels in accordance with applicable legislation.
Before scrapping, all plastic and rubber parts will have to be separated from the electrical material.
Most parts made from plastic, aluminium, copper or steel are suitable for recycling.
FAULT
CAUSE
ACTION
The cleaner fails to
start.
No power.
Check the power mains supply.
Check the integrity of the plug and power
cable.
Thermal magnetic switch tripped
Reset the thermal magnetic switch.
Loose wiring, incorrect voltage, or blown
fuse.
Check connections and power supply or
replace fuse.
Dust is leaking out
Perforated vacuum pipe.
Replace the pipe.
Perforated filter.
Replace the filter.
Filter unsuitable for type of job.
Fit a suitable filter for the type of material to be
vacuumed.
The vacuum cleaner
does not work as it
should.
Pipe perforated or blocked.
Check the pipe and, if necessary, replace.
ENDLESSBAG Section full
Replace ENDLESSBAG Section.
Filter blocked.
Replace filter.
Seals worn.
Clean the filter and if necessary change it.
Air leak.
Check for any air leaks out of closing
fasteners, tightening screws, Hopper or filter
chamber.
If problem has not been cured by any of the above actions, contact your local Trelawny SPT dealership for assistance.
PART NUMBER
DESCRIPTION
303.5282
Polyester Filter with 14 Pockets 20000 CM
2
Ø500
303.5289
Filter
-
Holder Seal Ø500
303.5493
Filter Clamp Ø500
303.5770
ENDLESSBAG bag (4 x 20m)
Summary of Contents for A45
Page 2: ......
Page 3: ......
Page 11: ...EXPLODED VIEW MOTOR HEAD ...
Page 18: ...NOTES ...
Page 19: ...NOTES ...