N-Platform Hardware Installation and Safety Guide
23
Warning!
This product requires short-circuit (overcurrent) protection, to be provided as part of the
building installation. Install only in accordance with national and local wiring regulations.
The TippingPoint 660N/TippingPoint 1400N power supply modules are hot-swappable. Refer to
on page 39 for information about hot-swapping modules.
Cabling requirements
Describes the cable requirements of the TippingPoint 660N/TippingPoint 1400N devices.
The TippingPoint 660N/TippingPoint 1400N ships with the following cables:
• Two AC power cables, one for each hot-swappable power supply
• Null modem cable for the serial console management port (DB-9 to RJ-45)
You can also receive a Right Angle IEC Receptacle power cord for the device. You can use this cable for
connecting power to the device in cases where you might not have enough room for a straight power
connection cable. This cable helps in situations when you need to install a device in a tight rack with a door.
The 90-degree bend in the female end of the cable prevents the cord from being pinched between the
device and the door.
Technical specifications
Provides links to topics that describe the hardware and software specifications of the TippingPoint 660N/
TippingPoint 1400N devices.
The following topics describe the hardware, interface, and software specifications for the
TippingPoint 660N/TippingPoint 1400N.
•
Hardware and interface specifications
•
Hardware and interface specifications
The following table provides technical specifications for the TippingPoint 660N/TippingPoint 1400N.
Specification
Description
Dimensions
2RU - 3.41 in x 16.84 in x 23.46 in (8.67
cm x 42.78 cm x 59.59 cm)
Weight
32.5 lbs (14.74 kg)