Install your TPS 8200TX and 8400TX security devices
Step 4. Add I/O modules
The 8200TX and 8400TX security devices come with blank modules inserted into all module slots.
Warning:
To enable the security device to cool efficiently, do not leave the module slots empty for an
extended period of time. Insert a blank module or an I/O module into each slot to ensure proper
ventilation.
The 8200TX and 8400TX security devices support the following I/O modules and bypass I/O
modules for fiber and copper components.
Warning:
The use of other vendor devices could be detrimental to proper operation of the
TippingPoint system.
The following
standard
I/O modules are supported for the 8200TX and 8400TX security devices and
are hot-swappable:
— TippingPoint 6-Segment Gig-T I/O module
— TippingPoint 6-Segment GbE SFP I/O module
— TippingPoint 4-Segment 10 GbE SFP+ I/O module
— TippingPoint 1-Segment 40 GbE QSFP+ I/O module
The following
bypass
I/O modules are supported for the 8200TX and 8400TX security devices and
are hot-swappable:
— TippingPoint 4-Segment Gig-T Bypass module
— TippingPoint 2-Segment 1G Fiber SR Bypass module
— TippingPoint 2-Segment 1G Fiber LR Bypass module
— TippingPoint 2-Segment 10G Fiber SR Bypass module
— TippingPoint 2-Segment 10G Fiber LR Bypass module
For more information on these supported I/O modules, refer to the product hardware documentation.
Add I/O modules
To remove the blank module, slide the slide latch (
1
) to the right and pull on the grab point (
2
).
Figure 2. TippingPoint TPS 8200TX and 8400TX security devices – blank module