Trend Micro™ Network VirusWall™ Enforcer 2500 Administrator’s Guide
5
-
10
F
IGURE
5-1.
The Appliance Firmware Flash Utility
2.
If the utility has not yet detected the Network VirusWall Enforcer 2500 device,
click
Detect
on the toolbar menu. The utility detects the Network VirusWall
Enforcer 2500 device connected to the computer and lists it in the detection table.
3.
Click the first row to select the detected device from the detection table.
4.
If the utility has not yet detected the Network VirusWall Enforcer 2500 device,
click
Detect
on the toolbar menu. The utility detects the Network VirusWall
Enforcer 2500 device connected to the computer and lists it in the detection table.
5.
Click the first row to select the detected device from the detection table.
6.
Click one of the following buttons to flash the corresponding firmware:
•
Flash BIOS
•
Flash BMC
Updating the BMC firmware disrupts the LAN connection temporarily. This
disruption happens if the utility runs while the Network VirusWall Enforcer
2500 device is still connected to the LAN. To prevent this disruption from
happening, disconnect the Network VirusWall Enforcer 2500 device from its
LAN connection before entering rescue mode.
WARNING!
If the BMC update is unsuccessful, using the AFFU, will no longer
work. Contact Trend Micro support if this issue occurs.