Viewing Status, Logs, and Summaries
4
-
9
enumerates all possible LCD module error logs:
E
RROR
C
ODE
AND
M
ESSAGE
C
AUSE
AND
P
OSSIBLE
W
ORKAROUND
/S
OLUTION
100
Corrupted image
The Network VirusWall firmware is corrupted. Reload the Network
VirusWall image.
101
Missing file
Missing boot file. Network VirusWall will try to boot from the second
partition.
102
Device failure
Missing boot file or physically damaged boot partition. Contact
technical support.
200
Corrupted file
Corrupted configuration file. Reload the Network VirusWall image.
201
Cannot open file
Unable to open the configuration file. The file may be missing or
corrupted. Reload the Network VirusWall image.
202
Cannot read file
Unable to read the configuration file. The file may be missing or
corrupted. Reload the Network VirusWall image.
203
Missing CM server
Cannot register the device to the Control Manager server. Check
the network and Control Manager server status.
205
No connection
Network connection unavailable. Check the network cable, as well
as the network status.
206
Cannot get key
Unable to obtain the public encryption key. The Network VirusWall
Enforcer device cannot register to the Control Manager server.
Check the E2EPublic.dat through the LCD module or
Preconfiguration console.
207
Cannot synchronize
time
Unable to synchronize time with the Control Manager time server.
The device cannot register to the Control Manager server. Ensure
that the Control Manager time service is running.
208
Cannot register
Unable to register the device to the Control Manager server. Check
the network and Control Manager settings.
209
Unknown error
The LCD module is unable to obtain the error from the Network
VirusWall function. The LCD module may be corrupted or
damaged. Contact technical support.
210
Cannot restore
Unable to restore the Network VirusWall factory default settings.
The Network VirusWall image may be corrupted. Reload the image.
211
IP conflict
The two devices in a failover pair have the same IP address. The
devices must have unique IP addresses. Change the IP addresses
so that the devices do not share the same IP address.
212
Port Group error
The fiber cards have been removed, but the port group settings
have not been altered to reflect this change.
T
ABLE
4-2.
LCD module error logs