Troubleshooting and FAQs
5
-
9
Note:
The account used to log on to the computer on which the Appliance Firmware
Flash Utility will run must have administrator rights or should belong to the
Administrators group. Otherwise, the utility cannot successfully execute.
b.
Configure the Local Area Connection properties to use the following
settings:
•
IP address– 192.168.252.100
•
Netmask– 255.255.255.0
•
Default Gateway– blank
•
DNS– blank
•
Firewall– disabled
c.
Connect one end of a crossover Ethernet cable to the computer's LAN port
and the other end to Port 5 of the Network VirusWall Enforcer 2500 device.
After completing these tasks, you are now ready to run the Network VirusWall
Enforcer 2500 Appliance Firmware Flash Utility.
Running the Appliance Firmware Flash Utility
Ensure that you have completed the initial tasks described in
this utility.
To run the Appliance Firmware Flash Utility:
1.
Insert the
Trend Micro Solutions CD for Network VirusWall Enforcer 2500
, select
the Appliance Firmware Flash Utility, and then click
Launch
.
The main console appears and automatically searches for connected Network
VirusWall Enforcer 2500 devices.