Trend Micro™ Network VirusWall™ Enforcer 2500 Administrator’s Guide
5
-
22
Control Manager and Network VirusWall Enforcer 2500
Communication Issues
Tip:
Refer to the
Getting Started Guide
>
Control Manager and Network VirusWall
Enforcer 2500 Integration
for additional information.
When troubleshooting the Control Manager and Network VirusWall Enforcer 2500
integration and communication:
•
Check the Network Time Protocol (NTP) used (see
)
•
)
Check the Network Time Protocol (NTP) in Use
Windows Network Time Protocol (NTP) and Control Manager NTP are both time
servers. Windows NTP may provide some other features for Active Directory Server
(ADS) endpoints. In addition, Windows NTP does not work unless you have installed
ADS.
To enable NTP:
38
Automatically logged
off the
preconfiguration
console
If you change the current window size, Network VirusWall Enforcer
2500 automatically logs off.
39
Unable to download
Pattern File History
using DNS
Try to use a different DNS server.
40
Unable to upgrade
from Network
VirusWall 2500 to
Network VirusWall
Enforcer 2500
This version of Network VirusWall Enforcer 2500 does not support a
direct upgrade. The release build cannot be used for upgrading the
device from version 1.8 to 2.0.
Update the boot image (NVW_image.2.0.1358.en_US.B) first. Then
reboot and follow the standard upgrade procedure in the
Upgrade
Guide
.
#
ISSUE
CORRECTIVE ACTION
T
ABLE
5-3.
Troubleshooting Network VirusWall Enforcer 2500 configuration
issues