MBS1000 Installation Guide
5-1
Trenton Systems, Inc.
Chapter 5 - Chassis Specifications
E
NVIRONMENTAL
Temperature
Operating
5
°
C to 40
°
C typical
Storage
-20
°
C to 70
°
C
Cold Excursion Temp
-40
°
C for up to sixteen hours
Relative Humidity
8% to 85% RH @ -12
°
C dew point, non-condensing
Specific operating temperature ranges for the MBS1000 are dependent on the option card type as well as
any other customer-installed system components such as hard drives. Extended operating temperature
CPUs resulting in a system’s achievable operating temperature range higher than what is stated here may
be available for use on the modular blade card inside the MBS1000. The reverse can also be true in that a
system subcomponent could have a lower operating temperature range that could lower the system’s
overall operating temperature range. Contact Trenton for more details.
E
LECTRICAL
–
MBS1000-002
S
YSTEM
C
ONFIGURATION
Line Voltage
100-240VAC, 10A/5A
or
200-250VDC at 5.5A
Line Frequency
50-60Hz
Power Consumption
450W typical, 900W max.
P
HYSICAL
Approximate Dimensions
(W x H x D)
17” x 1.75” x 28”
432mm x 44.5mm x 711mm
Net Weight
35.2 lbs. (16.0 kg)
(doesn’t include an option card)
S
HOCK
&
V
IBRATION
Shock - Class 3M4 operational and non-
operational under EN60721-3-3
10G operating; 100m/s
2
; Type I
Vibration - Class 3M4 operational and
non-operational under EN60721-3-3
Sinusoidal Vibration: 1G; 3mm; 10 m/s2; 2-9 9-200Hz
A
GENCY
A
PPROVAL
UL
UL recognized product listed in file #E208896-A5-UL
dated 2015-11-03
Environmental
IEC 60721-3-3:2002 including Class 3K3, 3Z3, 3Z4,
3M4 and 3S2
IEC 60721-3-2:1997 including Class IE23 and 2M3
CE – ECM Directive 2004/108/EC
including EMI/EMC
IEC61000-6-4:2006 & IEC61000-6-2:2005 including:
CISPR22:1997 + A1:2000 + A2:2002ClassA,
IEC61000-3-2:2005, IEC61000-3-3:2008, IEC61000-4-
2:2008, IEC61000-4-3:2008 + A1:2010, IEC61000-4-
4:2004 + Al:2010, IEC61000-4-5:2005, IEC61000-4-
6:2008, IEC61000-4-8:2009 & IEC61000-4-11:2004