28
Trevi Spa User Guidea
P1-ER
Pump 1 error
The system has detected no change in current when pump 1 is activated or stopped.
▪
Make sure that pump 1 is connected properly (you should hear a click when properly connected).
▪
Change the output status
(on/off)
of pump 1 and try all possible conditions (i.e. low, high, and stop).
▪
Reset the
Spa Pack
by pressing the
Select
button twice.
▪
If the error is not cleared, the problem is surely pump 1. It must be replaced.
▪
If pump 1 is replaced, learning mode must be performed again.
P2-ER
Pump 2 error
The system has detected no change in current when pump 2 is activated or stopped.
▪
Make sure that pump 2 is plugged in correctly (you should hear a click when properly done).
▪
Change the output status
(on/off)
of pump 2 and try all possible conditions (i.e. low, high, and stop).
▪
Reset the
Spa Pack
by pressing the
Select
button twice.
▪
If the error is not cleared, the problem is surely pump 2. It must be replaced.
▪
If pump 2 is replaced, the learning mode must be performed again
.
P3-ER
Pump 3 error
The system has detected no change in current when pump 3 is activated or stopped.
▪
Make sure that pump 3 is plugged in correctly (you should hear a click when properly done).
▪
Change the output status
(on/off)
of pump 3 and try all possible conditions (i.e. low, high, and stop).
▪
Reset the
Spa Pack
by pressing the
Select
button twice.
▪
If the error is not cleared, the problem is surely pump 3. It must be replaced.
▪
If pump 3 is replaced, the learning mode must be performed again.
CP-ER
Circulation pump error
The system has detected no change in current when the circulation pump is activated or stopped.
▪
Make sure that the circulation pump is plugged in correctly (you should hear a click when properly done).
▪
Change the output status by changing the set value.
▪
Reset the
Spa Pack
by pressing the
Select
button twice.
▪
If the error is not cleared, the problem is surely the circulation pump. It must be replaced.
▪
If the circulation pump is replaced, the learning mode must be performed again.
BL-ER
Turbine error
The system has detected no change in current when the turbine is activated or stopped.
▪
Make sure that the turbine is plugged in correctly.
▪
Change the output status
(on/off)
of the turbine.
▪
Reset the
Spa Pack
.
▪
If the error is not cleared, the problem is surely the turbine. It must be replaced.
▪
If the turbine is replaced, the learning mode must be performed again.