30
Trevi Spa User Guidea
SC-ER
System learning error
When an internal option is changed, the system must relearn the currents associated with each output/load. During this
learning mode, the device connected to Di (direct output, no relay) must be disconnected
IF IT REQUESTS MORE ThAN 0.4A.
Otherwise, the system will detect an SC error code
▪
Disconnected load.
▪
Restart the learning mode by pressing the Select button for 5 seconds.
▪
Press Change as many times as you need for all internal programming settings.
▪
When the procedure is completed, the accessory connected to the Di can be reconnected.
The keyboard does not work
Note: the keyboard connected to
in.xm
is detected only when the main circuit breaker is reset. Do not forget to trip and then
reset the circuit breaker if you change the keyboard model (the in.k400 for the in.k600).
If a keyboard does not work:
▪
Check the connections of the keyboard and try a replacement keyboard.
▪
Replace the keyboard if the problem is solved.
▪
Replace
in.xm
if the problem persists.
Notes
Spa Pack in.xe error codes
HR
An internal
in.xe equipment error was detected.
▪
Restart the
Spa Pack
; then start and stop all pumps and turbine.
▪
If the error reappears, replace the
Spa Pack in.xe.
Prr
The system has detected a problem in the control probe. The system constantly checks if the control
probe readings are within normal limits.
▪
Check the connection of the control probe (located above the heater).
▪
If the problem persists, replace the water heater.
▪
Replace the
Spa Pack
if the problem persists.
HL
The water temperature at the water heater reached 119°F (48°C). Do not enter the water!