Page 18
Step 3.
Depress First Part switch to load first contact
Step 4.
Open the funnel and observe if a contact is present. If contact is
present, let the funnel close and proceed to Step
5. If no contact is present, repeat Step 3
Step 5.
Obtain a properly stripped conductor Select the proper "G" dimension
setting. See Table 4-1.
TABLE 4-1. EXTERNAL "G" SELECTIONS.
SETTING # = WIRE SIZE #
For 22 gauge contacts:
1 =
26 AWG
2 =
24 AWG
3 = 22 AWG
For 20 gauge contacts:
4 = 24 AWG
5 =
22 AWG
6 =
20 AWG
“G” Selector
Contacts loading in feed tube are controlled by Feed Tube Sensor. If
feed tube is full, the sensor detects, and shuts off feeder bowl. As feeder
tube empties, sensor detects and feeder bowl is turned back on.