When the Transfer Arm reaches the vertical position, a limit switch (LS-
is engaged and the following events occur:
-Limit Switch sensor (S-2) is turned on
-High pressure is supplied to Slide Cylinder, allowing it to stay in the full extended
position.
-V-3 is deactivated closing funnels
-Shuttle Cylinder (EC-1) is activated, allowing a contact to be advanced from the
feeder tube to the drop tube.
If the contact exits the Drop Tube and seats properly in the Transfer Tip, adequate
vacuum will exist to switch on the Transfer Tip Sensor, (S-6). Supply for Vacuum
Sensor switch is provided by Vacuum Generator (VG-1).
If a contact does not seat properly in the Transfer Tip, the cycle will terminate until
reset.
With S-6 turned on again, V-2 is turned off, allowing the Transfer Arm to return to the
"ready to crimp" position.
The TAC is now ready to have another properly stripped conductor inserted in the wire
funnel and commence another crimping cycle.
.
Feed Tube
Drop Tube
Shuttle
Summary of Contents for TAC-10X
Page 5: ...Page 5 Figure 1 1 TAC 10X Front View ...
Page 7: ...Page 7 Figure 1 2 Wire Insertion Through Funnel ...
Page 10: ...Page 10 Figure 2 1 Pneumatic Hook Ups Air Off Air On ...
Page 16: ...Page 16 Crimp Inspection Points Improper Crimps Figure 3 3 Crimped Samples ...
Page 24: ...Page 24 Figure 6 1 TAC 10X Pneumatic Control Panel ...
Page 25: ...Page 25 Figure 6 2 TAC 10X Components Right View ...
Page 26: ...Page 26 PLC Controller Switching Power Supply Figure 6 3 TAC 10X Components Left View ...
Page 30: ...Page 30 ...
Page 31: ...Page 31 Carefully Remove Hose Clamp ...
Page 34: ...Page 34 ...
Page 38: ...Page 38 Figure 7 3 TAC 10X Pneumatic Diagram ...