Page 35
Step 21.
Crimp the conductor.
Step 22.
Inspect the crimp per required specifications.
Step 23.
Repeat Steps 19 through 22 for each conductor wire gauge to obtain
the necessary specimens; inspect per established procedure.
Step 24.
After all specimens have been produced, set the power on-off switch to
off and open the sleeve valve.
Step 25.
If crimps meet all established parameters, certify the TAC-10X for
production use, and establish a periodic verification schedule.