background image

13 

TSGGM – PARTS LIST 

Item  P/N 

Description 

Quan 

Item 

P/N 

Description 

Quan 

218215-20 

Weldment, Griddle 

TSGGM-18

 

24 

2425400

 

Pan, Grease 18" Short Draw 

Varies 

 

218216-20 

Weldment, Griddle 

TSGGM-24

 

 

2425500

 

Pan, Grease 24" Short Draw  

Varies 

 

218217-20 

Weldment, Griddle 

TSGGM-36

 

25 

8861000 

Label, Spec 

 

218218-20 

Weldment, Griddle 

TSGGM-48

 

26 

218215-12 

Panel, Back 

TSGGM-18

 

218215-11 

Body, 18" Firebox 

TSGGM

 

 

218216-12 

Panel, Back 

TSGGM-24

 

 

218216-11 

Body, 24" Firebox 

TSGGM

 

 

218217-12 

Panel, Back 

TSGGM-36

 

 

218217-11 

Body, 36" Firebox 

TSGGM

 

 

218218-12 

Panel, Back 

TSGGM-48

 

 

218218-11 

Body, 48" Firebox

 TSGGM

 

 

27 

8196601

 

Nut, U-Type 

21820728

 

Tube, Pilot Supply 

TSGGM-18

 

28 

22011193  

Panel, Control 

 

21820727

 

Tube, Pilot Supply 

TSGGM-24/36/48

 

Varies 

 

22011253

 

Panel, Control 

2066154 

Pilot, Top 

 

22011373 

Panel, Control 

 

2092800

 

Pilot, Broiler   

Varies 

 

22011493

 

Panel, Control 

22030005 

Support, Leg-18 

29 

30047501

 

Guide, Grease Slide 

Varies 

 

22030010

 

Support, Leg-24 

30 

8170700

 

Screw, 10-32x1/2, Type AB 

Varies 

 

22030015 

Support, Leg-36 

31 

8837120

 

Label, Orifice Size 

 

22030020

 

Support, Leg-48 

32 

22011195 

Baffle, Front Panel 18" 

218207-16 

Side, Grease Chute 

Varies 

 

22011255

 

Baffle, Front Panel 24" 

2092517

 

Plug, 1/8 NPTM 

Varies 

 

22011375 

Baffle, Front Panel 36" 

22031254

 

Side Panel, RH 

 

22011495 

Baffle, Front Panel 48" 

81546-00

 

#8 X 3/8 

33 

81973-00

 

T/S #10 X ½ TPB Tr Hd 

10 

218207-17 

Support, Burner-18 

36 

8353000 

Pop Rivet 

 

218208-17

 

Support, Burner-24 

37 

8633700

 

Leg, HD 2” Diameter W/Foot 

 

218209-17 

Support, Burner-36 

38 

8706300

 

Knob, Metal Cookline .375D shaft 

Varies 

 

218210-17

 

Support, Burner-48 

39 

8837129

 

Label, Instr.-location 

11 

2066844

 

Orfice, #44 

Varies 

40 

8832600

 

Label, Service Hotline 

12 

8417100

 

Nut, Hex, KEPS 10-32 

Varies 

41 

8837130

 

Decal, Oper. Instr. 

13 

2065643

 

Valve, Pilot 90° 

1/8NPT X 3/16CC TSGGM-18

 

Varies 

42 

2067300

 

Regulator, Convertible 3/4 ½ PSIG 

 

2068001

 

Pilot Valve 

TSGGM-24/36/48

 

Varies 

43 

8809920

 

Decal, Improper Install 

14 

21813075

 

Burner, "S” 

44 

8825300

 

Decal, Leg 

 

21813175

 

Burner, "U” 

Varies 

45 

8822325

 

Decal, UL Sanitation, NSF Std. 4 

15 

2068200 

Valve, Gas, On-Off 

Varies 

46 

43813103

 

Label, Warning, Hot Surface 

16 

8436200

 

Nut, Hex 5/16-18 S/S 

Varies 

47 

43813149

 

Label, Warning, Hot Surface 
(French) 

17 

8153100

 

#8-32 X 3/8 Type T 

Varies 

48 

2092903

 

Pilot Natural @ 6" W.C. 

Varies 

18 

218207-29 

Bracket, Pilot 

TSGGM-18

 

49 

2066850

 

Orfice, #50 

Varies 

 

218208-25 

Bracket, Pilot 

TSGGM-24/36/48

 

Varies 

50 

2092904

   

Orifice, Pilot L.P. 

Varies 

19 

21820715 

Manifold, 18" 

GCRB

 

52* 

8899300   

List Of Service Agencies 

 

22011199 

Manifold, 18" 

GCRB Pilot Safety

 

53* 

8838800

   

Manual, TSGGT-H/TSGGM-H 

Champion II

 

 

21820815

 

Manifold, 24" 

GCRB

 

55* 

8837201   

Bag, Cloth, 4"x6" W/drawstring 

 

21820830

 

Manifold, 24" 

GCRB Pilot Safety

 

56* 

8837190

 

Tag, Orifice Location 

 

21820915

 

Manifold, 36" 

GCRB

 

58* 

2065852 

Logo, TRISTAR 

 

21820930 

Manifold, 36" 

GCRB Pilot Safety

 

59* 

2092610 

Coupling, 3/4" Pipe X 3" Long 

 

21821015

 

Manifold, 48" 

GCRB

 

60* 

2092592

 

Nipple, 3/4 X Close Schd 40 Black 

 

21821030 

Manifold, 48" 

GCRB Pilot Safety

 

61* 

2092611

 

Elbow, 3/4 Black Pipe 

20 

22031254

 

Side Panel, LH  1    

62* 

2092613

 

Pipe, Black 3/4" X 23" 

Long Thrd Both 

Ends

 

21 

8163100

   

M/S Tr Hd Ph 10-32x1/4   

Varies 

 

 

 

 

22 

21813085   

Spacer 

Varies 

 

 

 

 

23 

22011191 

Baffle, 18" Front Heat 

 

 

 

 

 

218208-18

 

Baffle, 24" Front Heat 

 

 

 

 

 

218209-18 

Baffle, 36" Front Heat 

 

 

 

 

 

218210-18 

Baffle, 48" Front Heat 

 

 

*NOT SHOWN 

 

 
 

Summary of Contents for TSGGM-18i

Page 1: ...Date Purchased FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment P N 882213 REV 9 13 TRI STAR M...

Page 2: ...it s individual shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or l...

Page 3: ...its operation is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual alert you to hazards to the operator service personnel or the equipment The words are defined as follows DANGER This symbol warns of imminent hazard which will result in serious injury or death WAR...

Page 4: ...61 17 3 4 451 3 25 000 7 3 75 000 22 6 10 15 25 TSGGT 48i 48 1220 26 661 17 3 4 451 4 25 000 7 3 100 000 29 3 6 10 15 25 TSGGM 18i 18 457 26 661 17 3 4 451 1 37 500 11 37 500 11 6 10 15 25 TSGGM 24i 24 610 26 661 16 3 4 426 2 25 000 7 3 50 000 14 6 6 10 15 25 TSGGM 36i 36 915 26 661 16 3 4 426 3 25 000 7 3 75 000 22 6 10 15 25 TSGGM 48i 48 1220 26 661 16 3 4 426 4 25 000 7 3 100 000 29 3 6 10 15 2...

Page 5: ...440 PART 2 BS 6891 THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE MUST BE INSTALLED IN A WELL VENTILATED AREA Ventilation requirements ie B S 5440 LIGHTING INSTRUCTIONS TSGGT and TSGGM Griddles are furnished with either a pilot safety valve or a standing pilot not available in the European Community Please follow the instructions for your unit Pilot Safety Valve Lighting In...

Page 6: ...he unit Wherever possible avoid open windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable worki...

Page 7: ...nt may be used on the plate surface to help clean it but care must be taken to be sure the detergent is thoroughly removed After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry cloth To remove discoloration use a nonabrasive cleaner After each weekly cleaning th...

Page 8: ...es to the size recommended for propane L P For units with a pilot safety valve you must also change the pilot orifice to the other pilot orifice supplied 4 Replace the orifice fittings into the valve 5 Replace the front panel and knobs 6 Before installing the regulator unscrew the octagonal cap With the brass portion of the cap up you can read NAT on the plastic insert Snap the insert out of the c...

Page 9: ...me 10 to the right and for the 48 TSGGT repeat this twice more 10 to the right always remaining 10 5 8 from the splash guard After all locations are marked center the temperature probe on each marked location and then trace a circle around the probe This procedure will place the temperature probe over the center of each thermostat bulb and this is the only place temperature readings should be take...

Page 10: ...crease the temperature approximately 24ºF turn counterclockwise will increase the temperature approximately 24ºF Adjust and re measure the average temperature until you get the temperature to your desired point NOTE avoid making more than turn at a time Calibration is not linear and you can get the thermostat significantly out of calibration to a point where it is difficult to reset If after adjus...

Page 11: ...ning into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food is undercooked inside Heat is s...

Page 12: ...12 PARTS LISTS EXPLODED VIEWS TSGGM GRIDDLES EXPLODED VIEW ...

Page 13: ...shaft Varies 218210 17 Support Burner 48 2 39 8837129 Label Instr location 1 11 2066844 Orfice 44 Varies 40 8832600 Label Service Hotline 1 12 8417100 Nut Hex KEPS 10 32 Varies 41 8837130 Decal Oper Instr 1 13 2065643 Valve Pilot 90 1 8NPT X 3 16CC TSGGM 18 Varies 42 2067300 Regulator Convertible 3 4 PSIG 1 2068001 Pilot Valve TSGGM 24 36 48 Varies 43 8809920 Decal Improper Install 1 14 21813075 B...

Page 14: ...14 TSGGT GRIDDLES EXPLODED VIEW ...

Page 15: ... X TPB Tr Hd 4 15 21821915 Manifold TSGGT 18H 1 53 43813149 Label Warning Hot Surface French 1 21822029 Manifold TSGGT 24H Varies 54 21821920 Bracket Pilot Top T Pile TSGGT 18 1 21822130 Manifold TSGGT 36H 1 21814036 Bracket Pilot TSGGT 24 36 48 1 21822029 Manifold TSGGT 48H 1 55 8861000 Label Spec 1 15 21821930 Manifold TSGGT 18H Pilot Safety 1 56 43813103 Label Warning Hot Surface 1 21822030 Man...

Page 16: ...TAR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and during regular straight time hours Travel outside of the 35 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user Defectiv...