4
WARNING:
Keep the appliance free & clear of all combustible substances. If gas odor is
detected at any time, immediately shut unit down at the main shutoff valve. Do not permit
any open flames in the area of the appliance. Immediately contact an authorized Service
Agency or your local Gas Supplier for service.
WARNING:
Do not obstruct either the air inlet (underneath unit) or the ventilation air (back
of unit). Provisions must be provided to provide an adequate air supply to the griddle.
NOTICE:
Local codes regarding installation vary greatly from one area to another. The
National Fire Protection Association, Inc., states in its NFPA96 latest edition that local
codes are "Authority Having Jurisdiction" when it comes to requirement for installation of
equipment. Therefore, installation should comply with all local codes.
SPECIFICATIONS AND DIMENSIONS
MODEL
WIDTH
IN. (MM)
DEPTH
IN. (MM)
HEIGHT
IN. (MM)
# OF
BURNERS
BTU/kw
PER
BURNER
TOTAL
BTU/kW
HOUR
W.C.
IN.('Mbar')
TSGGT-18i
18 (457)
26 (661)
17-3/4(451)
1
37,500/11
37,500/11
6/10(15/25)
TSGGT-24i
24 (610)
26 (661)
17-3/4(451)
2
25,000/7.3
50,000/14.6
6/10(15/25)
TSGGT-36i
36 (915)
26 (661)
17-3/4(451)
3
25,000/7.3
75,000/22
6/10(15/25)
TSGGT-48i
48 (1220)
26 (661)
17-3/4(451)
4
25,000/7.3
100,000/29.3 6/10(15/25)
TSGGM-18i
18 (457)
26 (661)
17-3/4(451)
1
37,500/11
37,500/11
6/10(15/25)
TSGGM-24i
24 (610)
26 (661)
16-3/4(426)
2
25,000/7.3
50,000/14.6
6/10(15/25)
TSGGM-36i
36 (915)
26 (661)
16-3/4(426)
3
25,000/7.3
75,000/22
6/10(15/25)
TSGGM-48i
48 (1220)
26 (661)
16-3/4(426)
4
25,000/7.3
100,000/29.3 6/10(15/25)
Griddle Surface Dimensions
MODEL
WIDTH
IN. (MM)
DEPTH
IN. (MM)
TSGGT-18i and TSGGM-18i
17 13/16” / (452)
19 ½” / (496)
TSGGT-24i and TSGGM-24i
23 13/16” / (605)
19 ½” / (496)
TSGGT-36i and TSGGM-36i
35 13/16” / (910)
19 ½” / (496)
TSGGT-48i and TSGGM-48i
47 13/16” / (1215)
19 ½” / (496)
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas types, as shown on unit nameplate agrees with one another.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1-1996, the National Gas Installation
Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2 as applicable and in accordance
with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the unit
by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary
to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.