TRI TOOL INC.
92-0116 Rev. 210906
16
3. Align the slot.
4. Rotate drive shaft in a clockwise direction to align the slot. The rotation direction of the
input must be clockwise.
WARNING
WARNING: If the input is counterclockwise, minor or moderate injury, or property
damage will happen.
5. If you miss align, realign the slot.
6. Load the Model 550 around the tube to be cut.
7. Apply a light force to make sure that the Model 550 is over the tube.
8. Hold the Model 550 perpendicular to the surface of the tube to be cut.
9. Turn on the power for the Model 550 and begin the tube sever.
10. After the tube has severed, continue rotation, observing the cutting wheels until they
have returned to the home position.
11. Turn the power off.
12. Remove the Model 550 from the tube.