Problem: The Tool Holder is Not Feeding
The feed pin is broken or out of position.
The feed sprocket shear pin is broken.
The feed screw is stripped.
The feed nut is stripped.
The slide rails are too tight.
Problem: The Tool Bit is Diving and the BEVELMASTER
®
is Stalling
The Tool Bit is dull, chipped, etc.
The Tool Holder Adjustment Slide is to loose.
The Parting Tool Bit is leading the Beveling Tool Bit by to much for proper chip
clearance.
The Tool Bit is overextended.
The Tool Holder is overextended.
The Main Bearing pre-load is to loose.
Problem: The Pipe/Tube is Slipping in the Collet
The clamping pressure is not tight enough.
Scale and/or other foreign material is present on the pipe/tube.
Weld seams, swelling, or bumps are preventing full contact of the collet.
Dull Tool Bits are causing extra force in the axial and/or radial direction.
Problem: There’s a Loss of Air Power
The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.
Problem: The Air Motor Will Not Start
The air power supply is shut off.
The air motor is damaged and will not run free.
The air motor needs lubrication.
Add lubrication and do not run the air motor for a few minutes, then try
running the motor.
Lightly Tap on the side of the air motor casing with a piece of wood or with a
soft rubber mallet in case the vanes are sticking.
Sand or other foreign material may be in the vanes of the air motor.