6.1 New or existing installation 

  

• If the receiver functions at a shorter distance relative to the sensor, it is subject to interference or 
used outside the transmission range. 
•  Search  the  system  environment  for  changes  that  could  cause  the  interference  (for  example 
movement of metallic cabinets, furniture or partitions). 
• Use the sensor or receiver in a more suitable location. 
• Clear the receiver and perform a new learn process. 

     

6.2 Limitation of the range of the radio signals 

  

•  Transmitter/receiver  used  close  to  metallic  objects  or  close  to  materials  containing  metallic 
elements. Observe a distance of at least 10 cm. 
• Humidity in the materials. 
• Devices emitting high frequency signals such as audio and video systems, computers, electronic 
ballasts or fluorescent tubes. Observe a distance of at least 0.5 m. 

     

6.3 Contacts 

  

E-mail:...........................

contact@trio2sys.fr

 

 

   
 
 

  

This product can be sold and operated in the countries of the European Union.  

TRI

0

2

SYS

  hereby 

declares that the receiver 

10020076

 complies with the essential requirements and other relevant 

prescriptions of Directive 1999/5/EC R&TTE. For more details on the applied standards please 
consult website 

www.trio2sys.fr

  

       D.Girard

                                                                                                                                                                   

 

 

6. Troubleshooting 
ion and initial use

 

7. Declaration of conformity 

Summary of Contents for 02LINE 10020076

Page 1: ...ws without prejudicing the rights of the end customer that arise from the sales contract with his reseller If the event of exercising of a legitimate and regular right TRI02SYS may at its sole discretion rectify the device fault or supply a fault free device Any claim beyond this and all claims for consequential damages are excluded A legitimate fault exists if the device cannot be used at the tim...

Page 2: ...tance increases Where there is a line of sight connection the range is approximately 30 m in corridors and 100 m in large workshops or halls The range can be increased with an 02LINE repeater General characteristics Transmission frequency 868 3 MHz Transmission power 10 mW max 2 Safety 3 Technical characteristics EnOcean Equipment Profile A5 02 13 Measurement range from 30 C to 50 C Measurement re...

Page 3: ...e that averaged across the day the mean illuminance is 100 lux d The sensor s operating power reserve when fully charged in conditions of total darkness is 4 days Note The device is designed for external use To clean use a damp cloth 10020076 sensors transmit the measured temperatures using the frame described in the EnOcean Equipment Profiles EEP2 1 document A5 02 13 consultable under www enocean...

Page 4: ...e to metallic objects or close to materials containing metallic elements Observe a distance of at least 10 cm Humidity in the materials Devices emitting high frequency signals such as audio and video systems computers electronic ballasts or fluorescent tubes Observe a distance of at least 0 5 m 6 3 Contacts E mail contact trio2sys fr This product can be sold and operated in the countries of the Eu...

Reviews: