To set up the amplifier to be controlled by a 12V trigger:

Slide the POWER MODE switch to 

12V

.

Connect the 12V trigger cable from the trigger device to 

12V TRIGGER 

IN

.

(Optional) Connect 

12V TRIGGER OUT

 to another amplifier to link their 

power control together.

In this mode, the amplifier will turn on when a 12V signal is present on 

the 12V Trigger Input jack. This 12V trigger input can be wired to the 12V 

trigger output of a Triad audio matrix switch or a relay and contact on a 

Control4 controller. See the Control4 Knowledgebase for more details

NOTE: 

All amplifier zones turn on when a 12V trigger is received in 

12V Power Mode.

To set up the amplifier to be turned on by the audio sensing:

Slide the POWER MODE switch to 

AUDIO

.

In this mode, the amplifier will turn on when an audio signal is sensed on 

the audio input.

NOTE:  

Only the amplifier zone that senses audio will turn on when 

in Audio Power Mode.

TROUBLESHOOTING

RESETTING THE AMPLIFIER

•  Power reset

—Remove the power cord and replace the power cord to 

power cycle the device. 

NOTE: 

If the amplifier will not turn on, check the Power Mode 

switch. Try changing the Power Mode switch to 

ON.

LED TROUBLESHOOTING GUIDE 

Zone Status LED 

Power LED 

     Amplifier is powered on, in standby

     Amplifier zone(s) are on

     Zone(s) are in over-current protection

     Zone(s) are in thermal shutdown

SPECIFICATIONS

GENERAL

8-ZONE

4-ZONE

Triad Power Amplifier

TS-PAMP8-100

TS-PAMP4-100

Audio inputs

8 stereo, RCA style

4 stereo, RCA style

Global audio input

1 stereo analog (shared with 

zone 1 input)

1 stereo analog (shared with 

zone 1 input)

Global audio output

1 stereo analog (from shared 

zone 1 input)

1 stereo analog (from shared 

zone 1 input)

Zone speaker outputs

8 stereo outputs

4 stereo outputs

Global input

8 × 2-position dip switches

4 × 2-position dip switches

Bridge mode 

8 × 2-position dip switches

4 × 2-position dip switches

12V trigger control

1 × 3.5 mm (in)  

1 × 3.5 mm (out)

1 × 3.5 mm (in)  

1 × 3.5 mm (out)

Power mode switch

1 × 3-position switch—always 

on, 12V, or audio sense

1 × 3-position switch—always 

on, 12V, or audio sense

Wake from standby 

<2 seconds with 12V trigger 

~3 seconds with audio sense

<2 seconds with 12V trigger 

~3 seconds with audio sense

Standby power consumption

Less than 0.50W

Less than 0.50W

RATED WATTAGE

8-ZONE

4-ZONE

2 channels driven

100W per channel @ 4 

Ω

 

50W per channel @ 8 

Ω

  

100W per channel @ 4 

Ω

 

50W per channel @ 8 

Ω

  

RATED WATTAGE BRIDGED

8-ZONE

4-ZONE

1 bridged output

200W @ 8 

Ω

200W @ 8 

Ω

AUDIO

8-ZONE

4-ZONE

Frequency response

±0.4 dB, 10 Hz - 20 kHz,  

all loads

±0.4 dB, 10 Hz - 20 kHz,  

all loads

Dynamic range

110 dBA SE, 115 dBA BTL

110 dBA SE, 115 dBA BTL

Idle noise

45 uV, A-weighted, 20 Hz -  

20 kHz, SE

45 uV, A-weighted, 20 Hz -  

20 kHz, SE

Upper bandwidth, -3 dB

100 kHz, 4 

Ω

, SE

100 kHz, 4 

Ω

, SE

Input impedance

47 k

Ω

, f=1 kHz

47 k

Ω

, f=1 kHz

Output serial impedance

42 m

Ω

, f

1 kHz, SE

42 m

Ω

, f

1 kHz, SE

THD

0.003%, 4 

Ω

, SE, f=100 Hz, 

Po=1W

0.003%, 4 

Ω

, SE, f=100 Hz, 

Po=1W

POWER

8-ZONE

4-ZONE

AC mains power

Universal mains 100 - 240VAC 

50 - 60 Hz

Universal mains 100 - 240VAC 

50 - 60 Hz

Fuse rating

6.3A

6.3A

Power connection

IEC 320 C13 power connector 

with 3-pole detachable power 

cord

IEC 320 C13 power connector 

with 3-pole detachable power 

cord

THERMAL

8-ZONE

4-ZONE

Operating temperature

32 °F ~ 113 °F (0 °C ~ 45 °C)

32 °F ~ 113 °F (0 °C ~ 45 °C)

Humidity

5% to 95% non-condensing

5% to 95% non-condensing

Storage

-4 °F ~ 158 °F (-20 °C ~ 70 °C)

-4 °F ~ 158 °F (-20 °C ~ 70 °C)

Thermal dissipation

Three fans mounted in the 

left side

Three fans mounted in the 

left side

Thermal dissipation (heat losses)

0.23W / 0.8 BTU/hr, standby

40W / 136.5 BTU/hr, idle, all 

channels

100W / 341 BTU/hr, max 

output, all ch. driven

0.23W / 0.8 BTU/hr, standby

25W / 85.3 BTU/hr, idle, all 

channels

100W / 341 BTU/hr, max 

output, all ch. driven

MISCELLANEOUS

8-ZONE

4-ZONE

Mains switch w/ changeable fuse

Yes

Yes

Speaker outputs

2 × 16-position Phoenix-style 

connectors 

2 × 8-position Phoenix-style 

connectors 

Input gain potentiometer

1 for each zone 

1 for each zone 

Clip Indicator LEDs

1 for each zone (back panel)

1 for each zone (back panel)

H × W × D (with feet)

2.13 × 17.5 × 11.44"  

(5.3 × 44 × 29 cm) 

2.13 × 17.5 × 11.44"  

(5.3 × 44 × 29 cm) 

H × W × D (without feet)

1.75 × 17.5 × 11.44"  

(4.4 × 44.5 × 29 cm)

1.75 × 17.5 × 11.44"  

(4.4 × 44.5 × 29 cm)

Front panel power LED

1 × blue LED

1 × blue LED

Front panel zone status LED

1 RGB LED for each zone

1 RGB LED for each zone

REGULATORY/SAFETY INFORMATION

To review regulatory information for your particular Triad products, see the 

information located on the Triad website at 

triadspkrs.co/reg

.

WARRANTY

Limited 2-year Warranty. Go to 

triadspkrs.co/warranty

 for details.

Copyright ©2018, Control4 Corporation. All rights reserved. Control4, the Control4 logo, Triad, and the Triad logo 
are registered trademarks or trademarks of Control4 Corporation in the United States and/or other countries. All 
specifications subject to change without notice.

ALL

LINK TO GLOBAL INPUT

POWER MODE

ON
12V
AUDIO

2 3 4 5 6 7 8

1

2

3

4

5

6

7

8

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

GAIN

R

L

GLOBAL OUT

GLOBAL IN

L

R

CLIP

CLIP

CLIP

CLIP

CLIP

CLIP

CLIP

CLIP

AC POWER 100V-240V ~50-60Hz 105W

FUSE RATING T6.3A_H 250V

2 3 4 5 6 7 8

1

12V

TRIGGER

OUT

IN

L

R

L

R

L

R

L

R

L

R

L

R

L

R

L

R

ZONE

OU

TPU
TS

1

5

6

3
7

4
8

BRIDGE

BRIDGE

BRIDGE

BRIDGE

BRIDGE

BRIDGE

BRIDGE

BRIDGE

2

8 ZONE

POWER AMP

Reviews: