12
Method of Operation
Installer Mode
When button ‘B’ is pressed for 5 seconds with the unit turned off via button ‘A’, installer mode will be
activated.
Scroll through items by turning the dial E .
Select an item to change by pressing button E . Then, the user can change the value by rotating dial E .
After changing, press button E to save the setting.
When button B is pressed again, installer mode will be changed back to power off mode.
Index Numbers
Parameter
Description
1: EH
Error History
Previous fault codes (H0~H9)
2: cE
Clear Error History
Clears error history
3: In
System initialize
System reset
4: Fu
Flow units
L/m or GPM
5: FH
N/A
DO NOT ADJUST
6: FL
N/A
DO NOT ADJUST
7: dr
Reset Running time
Reset running time YES/No
8: dl
Reset igniting times
Reset igniting times YES/No
9: HA
High Altitude
High Altitude Setting (0: Nomal <1< 2<4 :High Altitude)
10: Cn
N/A
N/A
11: CI
N/A
N/A
12: Eh
N/A
N/A