LNB SKEW SETTING:
The 3 zones indicated in the illustration above
correspond to the numbered skew settings on the LNB
casing, only positions 2, 3 and 4 are relevant for the
British Isles.
Quality Installation Guidelines:
1. Do not use the antenna face to make setting adjustments, use the bracketry.
2. Ensure the Wall Mount Bracket is fastened with all 4 bolts, across at least 3 bricks and do not
use the mortar lines. Never fit closer than 3 brick courses from the top of a wall or within 2 brick
widths of an edge.
3. The antenna system must be assembled at the point of installation, do not transport pre-
assembled.
4. Ensure the LNB is at the correct skew setting for the area and the dish face is level and
secure. Always loosen the LNB clamp screw before adjusting the skew.
5. Do not over-tighten the bolts.
Copyright © 2016 TRIAX. All rights reserved. The TRIAX Logo and TRIAX, TRIAX Multimedia
are registered trademarks or trademarks of the TRIAX Company or its affiliates.
All specifications in this guide are subject to change without further notice.
TRIAX A/S | Bjørnkærvej 3 | DK-8783 Hornsyld | Denmark
triax.com/support