LNB SKEW SETTING: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

The 3 zones indicated in the illustration above 
correspond to the numbered skew settings on the LNB 
casing, only positions 2, 3 and 4 are relevant for the 
British Isles. 
 

 

 
 

Quality Installation Guidelines: 

 

1.  Do not use the antenna face to make setting adjustments, use the bracketry. 
 
2.  Ensure the Wall Mount Bracket is fastened with all 4 bolts, across at least 3 bricks and do not 
use the mortar lines.  Never fit closer than 3 brick courses from the top of a wall or within 2 brick 
widths of an edge. 
 
3.  The antenna system must be assembled at the point of installation, do not transport pre-
assembled. 
 
4.  Ensure the LNB is at the correct skew setting for the area and the dish face is level and 
secure.  Always loosen the LNB clamp screw before adjusting the skew. 
 
5.  Do not over-tighten the bolts. 