background image

  

 

EN

 

5

 

Technical Specifications: 

Range

 

 

Single 

6 or 8 

Single  

12 or 16 

Single 

24 or 32 

Cascade 

6 or 8 

Cascade 

12 or 16 

Cascade 

24 or 32 

 

 

outputs 

outputs 

outputs 

outputs 

outputs 

outputs 

Functionality 

 

1 x SAT position Multiswitch, single (stand-alone) or cascade versions 

LNB type  

 

1 x Universal QUATTRO LNB (AQ version uses QUAD LNB) 

 

LNB Inputs (SAT polarities) 

 

 

TER Input 

 

 

Trunk outputs (cascade) 

 

NA 

NA 

NA 

 Connectors 

Type 

F-connectors, IEC 60169-24, (female) 

 Impedance 

Ω 

75 

Frequency Range SAT 

MHz 

950-2400 

 Frequency Range TER  

MHz 

40-862 (active) / 5-862 (passive) 

 TAP Loss SAT 

dB 

-2…+3 ±2 

-2…+3 ±2 

-6…0 ±2 

-4…0 ±2 

-4…0 ±2 

-4…0 ±2 

 TAP Loss TER (active) 

dB 

-2 ±2 

-2 ±2 

-2 ±2 

-3 ±3 

-3 ±3 

-3 ±3 

 TAP Loss TER (passive) 

dB 

-24 ±3 

-24 ±3 

-24 ±3 

-33 ±3 

-33 ±3 

-33 ±3 

 THROUGH Loss SAT 

dB 

NA 

NA 

NA 

-2…-4 ±2 

-3…-4 ±2 

-2…-6 ±2 

 THROUGH Loss TER 

dB 

NA 

NA 

NA 

-3 ±2 

-2 ±2(12) 
-3 ±2(24) 

-2…-6 ±2 

 

Isolation T/S (typ.) 

dB 

30 

30 

30 

30 

30 

30 

 

Isolation H/V (typ.) 

dB 

30 

30 

30 

30 

30 

30 

 

In/Out Return Loss SAT 

dB 

>10 

>10 

>10 

>10

 

>10 

>10

 

 

In/Out Return Loss TER 

dB 

>10 

>10 

>10 

>10

 

>10 

>10

 

 

Max. Output Level SAT 
(IMD3 @ 35 dB) 

dBµV 

101 

101 

101 

101 

101 

101 

 

Max. Output Level TER  
(IMD3 @ 60 dB) - active 

dBµV 

90 

88 

88 

84 

84 

84 

 

LNB Supply Voltage 

VDC 

18 

18 

18 

18 

18 

18 

 

LNB Supply Current (Max.) 

mA 

500 

500 

500 

900 

900 

900 

 

Current cons. (from STB) 

mA 

27 

29…38 

29…38 

35 

27…35 

27…35 

 

Current Cons. (from PSU) 

mA 

120 

10…250 

10…250 

7 /  

100 

10 / 100…350  10 / 100…350 

 

Mains Voltage 

VAC/Hz 

90…264 /  

50-60 

90…264 / 

50-60 

90…264  / 

50-60 

NA 

NA 

NA 

 

DC connector 

Type 

None, -R types: RCA/cinch/phono female 

Cascade types: 5,5mm/2.1mm DC plug *) 

 

Switch Commands 

VDC/kHz 

 

13/18 VDC, 0/22kHz, DiSEqC 1.0 

 

Power Supply 

Type 

Fixed/ 

Included 

R-Type: none 

Fixed/ 

Included  

R-Type: none 

Fixed/ 

Included 

R-Type: none 

*) For external PSU w/EU-Mains plug:   

318150, TMS 1520-55, 2,0A, or 

318152, TMS 1533-55, 3,3A 

R-types can use: 318154, TMS 1520-RCA 

 

Please visit 

www.triax.com

 for details on individual weight, dimensions and part numbers 

 

 

Summary of Contents for TMS 5XX SE AQ-EU Series

Page 1: ... out active TER Single w PSU and EU Mains plug 6 32 out passive TER TMS 5XX SE P R Single no PSU for SAT receiver DC sourcing 6 32 out passive TER TMS 5XX CE A EU Cascade for external PSU 8 32 out active TER TMS 5XX CE P EU Cascade for external PSU 8 32 out passive TER Language EN Version 9 2016 A User Guide TMS 5XX SE CE Euro Line Multiswitch Series ...

Page 2: ...quirements set forth in EU safety standards e g EN 60065 and 50083 1 as well as any local requirements and standards for SAT IF and RF SMATV installations Exercise care and good practise when mounting coaxial connectors F connectors on the cables to avoid short circuits and unnecessary emission of noise and disturbance of neighbouring installations Only perform multi switch installation jobs while...

Page 3: ...hm terminators DC supply for LNBs and or Line Amplifier s can be done via the built in PSU P EU and A EU versions and can be done by attaching an external power supply to any of the TMS 5XX CE cascade units Cascade switches can also take DC Supply from the trunk lines if a PSU is connected elsewhere in the trunk DC is only needed for an active TER path the SAT path is always DC sourced by the STB ...

Page 4: ...ellite receivers and TV Please note that connector position and use may be different on other size units The cascade is shown terminated and power supplied via a TMS 5XX SE stand alone multiswitch This is optionally In a cascade the last cascade multiswitch may also be terminated at the end trunk and DC sourced via an external power supply Connect to 230 VAC Mains via EU plug Optional external Pow...

Page 5: ...Isolation T S typ dB 30 30 30 30 30 30 Isolation H V typ dB 30 30 30 30 30 30 In Out Return Loss SAT dB 10 10 10 10 10 10 In Out Return Loss TER dB 10 10 10 10 10 10 Max Output Level SAT IMD3 35 dB dBµV 101 101 101 101 101 101 Max Output Level TER IMD3 60 dB active dBµV 90 88 88 84 84 84 LNB Supply Voltage VDC 18 18 18 18 18 18 LNB Supply Current Max mA 500 500 500 900 900 900 Current cons from ST...

Page 6: ...nd updated manuals go to Copyright 2016 TRIAX All rights reserved The TRIAX Logo and TRIAX TRIAX Multimedia are registered trademarks or trademarks of the TRIAX Company or its affiliates All specifications in this guide are subject to change without further notice TRIAX A S Bjørnkærvej 3 DK 8783 Hornsyld Denmark ...

Reviews: