background image

Heating Mode

Heating Mode

08:20

01.07.2017

80%

Enter

Back

Casing type

Heating program No .

Casing diameter

Heating temperature

Heating time

Auto heating

6

40mm

4mm

150

19s

On

Heating Mode

Select the protection sleeve type 

Diameter of fiber protection sleeve

9

Summary of Contents for Lemon 3

Page 1: ...Fusion Splicer USER S GUIDE ...

Page 2: ......

Page 3: ...otherwise it will lead to fire or explosion When the fusion splicer is working do not touch the electrode avoid the hurt caused by the discharge of the electrode When replacing the electrode you must turn off the power and disconnect the power cord Please follow the operation manual strictly to use the battery Please do not charge the battery by using methods other than in the manual Don t throw t...

Page 4: ...ted to strong vibration and shocks otherwise the machine will be damaged Please use a dedicated carrier to transport or store the fusion splicer Using the battery The equipment can use a disposable alkaline battery or rechargeable battery and can not be mixed with different types or different capacity batteries Only rechargeable batteries can be charged Avoiding condensation Sudden changes in temp...

Page 5: ...Standard Package 3 Spare electrode Fiber stripper AC DC adaptor Carrying case Fiber cleaver User manual ...

Page 6: ...nti collision batten 8 Electrode cover Objective lens Electrode Windshield cover LED Optical fiber presser 7 Heat shrinker cover Heater V groove 10 Power supply socket 9 USB connector Multi functional clamp 13 14 5 8 7 11 10 9 13 12 3 2 4 1 15 16 6 Cooling tray 4 ...

Page 7: ...EFT RIGHT Key RESET Key START Key UP DOWN Key HEAT Key X Y Key ENTER Key Power on off Modify settings Motor reset Start splicing Move the cursor Start heating Back to previous menu Switch X Y images Enter into the menu Save settings 5 ...

Page 8: ...ving fiber Loading fiber onto splicer Start splicing Visual inspection on LCD during splice Taking out spliced fiber Centering sleeve to spliced point Centering sleeve in heater Start heating Splicing Operation Note Place fiber between electrodes tip and V groove end Hold Pull Marking 6 Turn on ...

Page 9: ...hen using navigation key to choose the different sub menu then press key again to enter into the sub menu Main Menu Splice Mode Heating Mode Function Setting System Setting 08 20 01 07 2017 80 Enter Back History Record Maintain 7 ...

Page 10: ...SM 1 Enter 120ms 3 0 Splice Mode Splice Mode SM MM DS NZDS Set fiber alignment limitation Manual Auto Half auto Set fiber alignment offset threshold Set current splicing program number Set splicing loss limit value Edit splicing parameters under current program No Set compensation arc time Clean tiny dust on fiber end by a short arc discharging Fine align Cladding align Core align Set the limit va...

Page 11: ...8 20 01 07 2017 80 Enter Back Casing type Heating program No Casing diameter Heating temperature Heating time Auto heating 6 40mm 4mm 150 19s On Heating Mode Select the protection sleeve type Diameter of fiber protection sleeve 9 ...

Page 12: ... test mode Reset waiting time Tension test Auto starting 6s On Function Setting On On Only valid when Tension test is Off If On splicer will auto adjust the discharge current If On it will execute tension test automatically after splicing If On it will auto start splicing 10 ...

Page 13: ...ower saving mode Restore factory settings Silent mode Enter 100 English Flip System Setting Enter Enter Enter Off System Setting System Setting 08 20 01 07 2017 80 Enter Back Month Year Date Hour Minute 2017 7 1 12 Time setup 30 08 20 01 07 2017 80 Enter Back Auto shutdown Auto sleep 10min Power saving mode Off 11 ...

Page 14: ... Enter Enter Enter Enter Enter History Record 08 20 01 07 2017 80 Enter Back No View records Total 42 Date Angle Loss Fiber type 0001 0003 0004 01 07 2017 01 07 2017 01 07 2017 0 0 0 0 0 0 SM SM SM 0 00 0 00 0 00 Pages 11 Current 1 0002 01 07 2017 0 0 SM 0 00 08 20 01 07 2017 80 Enter Back Query fault records Date Clock No 01 07 2017 12 30 01 07 2017 12 30 01 07 2017 12 30 0X00003115 01 07 2017 12...

Page 15: ...ers Correct led Enter Enter Enter Enter Enter Maintain Manual SM 1 60 6mm Discharge Reset 08 20 01 07 2017 Start 80 X Y Left Fiber 08 20 01 07 2017 80 Enter Back Arc correction Help 1st Place fiber and covering the wind cover 2nd Press ENTER key and follow the prompts NOTE Several times is needed Please wait patiently 13 ...

Page 16: ... the best splicing result please don t touch the electrode tip with hard objects while cleaning 08 20 01 07 2017 80 Enter Back Clean electrodes Help 1st Ensure that no fiber exist in the vision 2nd Press ENTER key and follow the prompts 14 ...

Page 17: ...no fiber exist in the vision 3rd Press ENTER key and follow the prompts NOTE After the operation is completed the number of discharge will be set to 0 Maintain Replace Electrodes 15 Remove the electrode cover Loosen screws Remove the old electrode Place the electrode cover Tighten screws Install the electrode cover ...

Page 18: ... or high loss Continuous overshoot during alignment detect system parameter 1 2 R 3 Long distance transportation and strong vibration 4 5 08 20 01 07 2017 80 Enter Back Detect system parameters Help 1st Clean the V grove place fiber and covering the wind cover 2nd Press ENTER key and follow the prompts NOTE This operation will last for a few minutes Please wait patiently 16 ...

Page 19: ...r Cleaning V groove Fiber Presser The Heater Objective Lens When cleaning keep the device Off Use cotton swab moistened with purity alcohol Do not touch the electrode tips Use dry swab to clean the excess alcohol 17 ...

Page 20: ...erent colors and shapes in various states Here are some examples of Battery information can also be viewed in the system menu Battery Information Remain 100 less than 10 shows red icon Charging Fully charging 100 10 50 100 AutoMode SM 1 60 6mm Splice Reset 08 20 01 07 2017 Place Fiber Align to splice 80 X Y 18 ...

Page 21: ...Cut the fiber again if the quality is poor please replace the fiber cleaver The angle error in both horizontal and vertical direction is greater than the set threshold value Replace the fiber on both sides Please clean the V groove redo the discharge correction and splice again Replace electrode and detect system parameters Please use the USB derive the original splicing record then delete them Pl...

Page 22: ...Improper setting of luminance of LED Please detect system parameters Please check if the fiber is properly placed and the connection is in good condition Restart the fusion splicer Please contact the after sales service Restart the fusion splicer Image abnormal The camera may have been damaged or connector interface is loose Restart the fusion splicer Sense abnormal The abnormal working of the sen...

Page 23: ...length Environmental conditions Power supply Size H W D Weight 1 83kg 164mm 141mm 138mm Li ion battery or AC DC input 13 5V 10 50 operation temperature 0 95 RH humidity 0 5000m altitude 40mm 60mm or others Auto Manual Half Auto 2 0N Standard 10000 results 5 0 inches colorful LCD display Typical 200 cycles splicing and heating 2500 24s Typical 8s with standard SM fiber Core alignment 0 02dB SM 0 01...

Page 24: ......

Reviews: