Warning Information
Timeout abnormal
Field abnormal
Light source abnormal
Detection abnormal
Storage abnormal
Communication anomaly, data has a packet loss
Failures in detecting system parameters
Heat shrinkable heater do not work properly
Data can't be saved
Long time during align splicing
Heat Shrink abnormal
Storage abnormal
Improper installation position of electrode
Restart align splicing
Detect system parameters first, if continue to
prompt abnormal, please re-install the electrode
Data abnormal
The fusion splicer is working in the abnormal state
Continue to align splicing, and it have no affect
Improper setting of luminance of LED
Please detect system parameters
Please check if the fiber is properly placed and
the connection is in good condition
Restart the fusion splicer
Please contact the after-sales service
Restart the fusion splicer
Image abnormal
The camera may have been damaged or connector
interface is loose
Restart the fusion splicer
Sense abnormal
The abnormal working of the sensor built-in the
fusion splicer
This abnormal does not affect the normal working
Electrode abnormal
Abnormal installation of electrode on both sides
Please ensure that electrodes of both sides are
aligned when installed, also ensure that both
sides are in the center of the V-groove
The mechanical structure was destroyed
Improper installation position of windshield cover
Warning
Reason
Treatment method