20
8.2
Annual Service (Available from your supplier)
•
The Tricel Puraflo system will require a full service (available from your supplier) once a year to
guarantee the efficiency of the system is maintained. Service personnel must be accommodated
with clear access to the system.
•
During routine servicing, the following items are checked if applicable:
Checks
Procedures
The general condition of the pump chamber is
good.
The vents in the sampling chamber are
cleared.
The pipework inside the pump chamber is
secure.
The electrical control panel and alarm
system are tested.
The pipework in the sampling chamber is
secure.
The pump and float switch are tested.
The lid of the sampling chamber is in good
condition.
The distribution outlets in the modules are
cleared of any blockages.
Condition of the media is inspected.
The level of the sludge in the septic
tank/primary storage chamber is measured.
The system is inspected for any obvious non-
wastewater infiltration into any compartment
(at the time of inspection).
The effluent filter in the septic tank is checked
and cleared of any blockages if required (only
applies to secondary system).
General appearance and condition of the
treatment system and the surrounding ground
area is good.
8.3
De-sludging
To ensure that the Tricel Puraflo system performs effectively, the septic tank/wastewater treatment plant
must receive regularly maintenance.
•
The de-sludging must be performed by qualified personnel. De-sludging is done with a vacuum
tanker (we recommend the use of a licensed company).
•
Please remove all floating and settled sludge from the septic tank/ primary chamber of the
wastewater treatment plant during de-sludging.
•
During the de-sludging, the effluent filter at the outlet of the septic tank should be removed
from its housing and hosed down to remove any materials which may result in blockage
(secondary treatment only).