background image

 

32 

 

Product 

Product 

Code 

This 

Tricel 

Puraflo 

is a 

Nominal Organic 

Daily Load 

(BOD5)

 

(kg/day) 

Nominal 

Hydraulic Daily 

Flow 

(QN)(litres/day) 

6P Puraflo Secondary  

221342 

  

0.36 

900 

6P Puraflo Tertiary 

221355 

  

0.36 

900 

9P Puraflo Secondary 

221343 

  

0.54 

1350 

9P Puraflo Tertiary 

221356 

  

0.54 

1350 

11P Puraflo Secondary  221344 

  

0.66 

1650 

11P Puraflo Tertiary 

221357 

  

0.66 

1650 

15P Puraflo Secondary  221345 

  

0.9 

2250 

15P Puraflo Tertiary 

221358 

  

0.9 

2250 

21P Puraflo Secondary  221346 

  

1.26 

3150 

21P Puraflo Tertiary 

221359 

  

1.26 

3150 

24P Puraflo Secondary  221347 

  

1.44 

3600 

24P Puraflo Tertiary 

221360 

  

1.44 

3600 

27P Puraflo Secondary  221348 

  

1.62 

4050 

27P Puraflo Tertiary 

221361 

  

1.62 

4050 

33P Puraflo Secondary  221349 

  

1.98 

4950 

33P Puraflo Tertiary 

221362 

  

1.98 

4950 

42P Puraflo Secondary  221350 

  

2.52 

6300 

42P Puraflo Tertiary 

221363 

  

2.52 

6300 

45P Puraflo Secondary  221351 

  

2.7 

6750 

45P Puraflo Tertiary 

221364 

  

2.7 

6750 

50P Puraflo Secondary  221352 

  

7500 

50P Puraflo Tertiary 

221365 

  

7500 

 

 

 

 

Tricel (Killarney) Unlimited Company Trading as Tricel 

Ballyspillane Ind. Est. Killarney, Co. Kerry, Ireland 

Tel:

 

+353 (0)64 663 2421

 

I

 Email:

 sales@tricel.ie I 

www.tricel.ie 

 

Tricel Environmental UK, A trading brand of Dewey Waters Ltd 

Heritage Works, Winterstoke Road, Weston-super-Mare, BS24 9AN, United Kingdom 

Tel:

 

44 (0) 1934 422 311 I 

Email:

 environment@tricel.co.uk I 

www.tricel.co.uk

 

 

 

In accordance with Tricel’s normal policy of product development these specifications are subject to change without notice.

 

Summary of Contents for 11P Puraflo Secondary

Page 1: ...1 125 Rev 4 Jan 2019 Tricel Puraflo 1 50 Wastewater Treatment Plants Engineering a green future...

Page 2: ...eatment 11 3 Tricel Puraflo Range 12 3 1 System Specifications 12 3 2 System Components 12 3 2 1 Tricel Puraflo Module 12 3 2 2 Effluent Filter secondary treatment only 13 3 2 3 Pump 13 3 2 4 Pipework...

Page 3: ...Conditions 21 10 Troubleshooting 23 10 1 Plant Operation 23 10 2 Odours 24 11 Certification 25 11 1 Declaration of Performance Tricel Puraflo with Tricel Fortis 25 11 2 Declaration of Performance Tric...

Page 4: ...4...

Page 5: ...5...

Page 6: ...e wastewater treatment system must be appropriately trained Suitable protective clothing including waterproof abrasion resistantgloves overalls safety footwear eye ear and respiratory protection goggl...

Page 7: ...hende sludgingand thereforethisshallneverbe donealone A wastewater treatment system that fails to fully treat sewage due to poor maintenance or overloading may allow excess nutrients phosphorus and ni...

Page 8: ...using little to no energy The Tricel Puraflo system works in conjunction with your septic tank or wastewater treatment plant The wastewater is distributed evenly over the top of the peat filter using...

Page 9: ...evenly onto the peat filter via a distribution grid at the top of each Puraflo module Stage 3 Liquid effluent undergoes treatment as it filters through the bio fibrous peat in the Puraflo modules Stag...

Page 10: ...er of modules depend on loadings 7 Sampling Chamber 8 DistributionBox Flowing topercolationarea pumpchambertodischarge treated liquid Some septic tanks may only have one manhole cover 2 2 2 Plan view...

Page 11: ...tank a pumping chamber with control alarm kiosk as well as the Puraflo modules with a sampling chamber 2 3 2 Tertiary Treatment Environmentally sensitive sites or sites that are restricted in terms o...

Page 12: ...2 7 9 1 3 3 10 11 1 4 4 12 15 3 2 6 16 21 4 2 8 22 24 3 3 9 25 27 5 2 10 28 33 6 2 12 34 42 5 3 15 43 45 4 4 16 46 50 6 3 18 3 2 System Components 3 2 1 Tricel Puraflo Module Dimension Unit Value A m...

Page 13: ...hose over the septic tank 3 2 3 Pump The submersible pump and float switch is fitted with a thermal overload protection Effluent from the septic tank or waste water treatment is pumped via a 1 5inch p...

Page 14: ...ted wastewater from the Puraflo modules and the pipeworkusedforthedispersion of wastewater on top of the peat inside the Puraflo modules is in accordancewithBS3505 1986 Specification for unplasticized...

Page 15: ...15 Important If you required drawings for larger Tricel Puraflo systems from 12 to 50PE please visit http ie tricel eu downloads...

Page 16: ...re ropes in contact with the modules Care is needed to control the lift to ensure the modules are not damaged The modules are designed for a single lift when placing them in position Always lift modul...

Page 17: ...result in reduced effectiveness and increased maintenance and orreplacementcostsinthelong term 8 1 Regular Maintenance 8 1 1 Septic Tank If applicable Theseptictankshouldbede sludgedwhenrequired Inacc...

Page 18: ...lter over the septic tank ensuring that all solids fall back into the septic tank Insert the filter cartridge back into the housing ensuring that the filter is properly aligned and inserted correctly...

Page 19: ...relation to the pump o Intheeventofanelectricalstormorpowerfailure thecircuit breakerswitchesoff theelectrical linesfeedingthepump The pump alarmshouldbecheckedtoseeif they tripped to the off positio...

Page 20: ...the septic tank primary storage chamber is measured The system is inspected for any obvious non wastewater infiltration into any compartment at the time of inspection The effluent filter in the septi...

Page 21: ...e done as soon as possible An electrical connection to the plant must be maintained for it to function correctly This ensures that theplanthasacontinuousairsupplyandwherenecessarythedischargepumpwill...

Page 22: ...meticandcleaningwipes Sanitarytowels Tampons Kitchenpaper Nappies Medication Servicepersonnelmustbeaccommodatedwithclearaccesstothesystem If others size the system we will supply to these specificatio...

Page 23: ...move freely Storm water flooding Redirect storm water drains Storm water must never enter the plant Discharge hose pipe blocked Find blockage and remove or replace damaged hose pipe Pump runs intermi...

Page 24: ...in the drains are fitted and the joints sealed Air vent on pipe work not installed correctly Ensure all effluent pipes are vented correctly Vents are normally fitted to all pipes and they should be h...

Page 25: ...RP Technology Septic tank with bio fibrous peat filter Components Septic tank Pump chamber bio fibrous peat modules alarm 4 Intended for Use To treat domestic wastewater for up to 50 population equiva...

Page 26: ...ad of 0 33kg d and hydraulic daily load of 0 9m 3 d Determined at temperatures 12 0 Material Performance Essential Characteristics Method Performance Harmonised Technical Specification Water Tightness...

Page 27: ...r finstitut f r Abwassertechnik GmbH Hergenrather Weg 30 52074 Aachen Number NB 1739 Treatment design capacity Nominal organic daily load BOD5 Nominal Hydraulic daily flow QN As Set Out in Table CE fo...

Page 28: ...s peat modules alarm 4 Intended for Use To treat domestic wastewater for up to 50 population equivalent 5 Name Address and Contact Information of Manufacturer Tricel Killarney Unlimited Company tradin...

Page 29: ...s obtained at average organic daily load of 0 33kg d and hydraulic daily load of 0 9m 3 d Determined at temperatures 12 0 Material Performance Essential Characteristics Method Performance Harmonised T...

Page 30: ...rance Number NB 1164 Puraflo Notified Body Pr finstitut f r Abwassertechnik GmbH PIA Hergenrather Weg 30 52074 Aachen Germany Number NB 1739 Treatment design capacity Nominal organic daily load BOD5 N...

Page 31: ...31...

Page 32: ...Puraflo Tertiary 221361 1 62 4050 33P Puraflo Secondary 221349 1 98 4950 33P Puraflo Tertiary 221362 1 98 4950 42P Puraflo Secondary 221350 2 52 6300 42P Puraflo Tertiary 221363 2 52 6300 45P Puraflo...

Reviews: