Discharge hose/pipe blocked
Find blockage and remove or replace damaged
hose/pipe
Alarm is sounding
but the pump and
blower are
working
Air return pipe to the alarm
not returning an air signal.
Electrical fault.
The electrical panel is wet
Check that the air pipe is not damaged or bent. Ensure
there is air blowing through this pipe. Check that the
pipe is inserted to the alarm correctly.
Get a qualified person to check that the alarm is
installed correctly.
Get a qualified person to check that the alarm is
installed correctly.
Please Note:
Before taking any corrective action, always positively identify the real source of the odour. Check if the odour is
coming from another outside source such as a storm drain. All wastewater disposal plants vent gases back
through soil pipe and out roof vents. Improperly installed roof vents can cause odour problems. Traps in
drains prevent odours from entering the home. To function they must contain water and be sealed correctly.
Symptom
Possible causes
Corrective action
Effluent odour
directly outside
the house or inside
the house
Pipe connections to toilets /
drains not connected correctly.
Air vent on pipe work not
fitted or fitted incorrectly
Pipe work is damaged or
blocked or fitted
incorrectly
Check that the traps / U - bends in the drains are
fitted and the joints sealed
Ensure all effluent pipes are vented correctly, vents
are normally fitted to all pipes and they should be
higher that the eve of the roof.
Inspect pipe work to ensure it is undamaged and
clear of obstructions or sagging.
Bad effluent odour
directly over the
tank
Pipe work to or from the tank
is blocked
Chemical kill of bacteria
No air delivery
Hydraulic/Organic
overloading Tank vent
blocked
Check the level of liquid in the tank. Ensure the
pipes are not blocked and are fitted correctly to the
tank.
Ensure pumps are working properly if applicable.
If symptom persists for 48 hours or more, remove
all liquid and replace with clean water
Check
blower
is
functioning
properly
Reduce flow and/or organic
load
Clear tank vents
In accordance with our normal policy of product development, this specification is subject to change without
notice. April 2014.