7
WARNING: THIS APPLIANCE MUST BE EARTHED
RATING PLATE
This is situated on the lower front frame of the
appliance and can be seen upon opening the door.
Alternatively the rating plate may also be found on
the back or top of some models (where applicable).
The appliance must be protected by a suitably rated
fuse or circuit breaker. The rating of the appliance is
given on the rating plate.
Do not remove the rating plate from the appliance
as this may invalidate the guarantee.
INSTALLATION
If your appliance has been damaged in transit,
contact your supplier immediately.
DO NOT
attempt
to install it.
Your appliance left the factory fully packaged to
protect it from damage. If it is delivered without
packaging and damage has occurred, the
manufacturer cannot accept responsibility. Contact
your supplier for advice.
Once the packaging has been removed the appliance
should only be moved by hand.
DO NOT
use a sack
barrow or any other aid to lift the appliance as
damage may occur.
Connection to the electricity supply must be carried
out by a qualified electrician/competent person.
The electrical connection should be made using a
double pole isolating switch (cooker socket) with at
least 3mm contact separation in all poles. The cable
must have conductors of sufficiently high cross-
sectional area to prevent overheating and
deterioration.
The recommended cross-section area is six square
millimetres (6.00mm
2
).
SB 412WTS
The electrical connection must be made using an all
pole isolating switch, or other suitable means of
disconnection, with at least 3mm contact separation.
The cable must have conductors of sufficiently high
cross-sectional area to prevent overheating and
comply with all relevant wiring regulations.
The cable should be routed away from potentially hot
areas marked by 'X' in the diagram below.
To move the appliance, open the main oven door,
and lift the appliance by holding inside the top of the
oven compartment.
This is a type 'Y' appliance, which means it is free-
standing and can be fitted with cabinets on one or
both sides.
Side walls which are above hob level should be
protected by heat resistant non-combustible material
and MUST NOT be nearer than 40mm to the hob
side.
A nominal air gap of 2mm at either side of the
appliance is required to enable the appliance to be
moved into position.
Overhanging surfaces or a cooker hood should be a
minimum of 685mm above the hob.
It is important to ensure that the appliance is level
after installation. Levelling feet are fitted to the
appliance to accommodate uneven floors.