34
contact your local water authority.
Electrical connection
Information on the electrical connection is
given on the rating plate on the inner edge of
the appliance door and in the chapter
«Technical Data».
Check that your domestic electrical installation
can take the maximum load required, also
taking into account any other appliances in
use.
Attention!
Connect the machine to an earthed socket.
The manufacturer declines any responsibility
for damage or injury through failure to comply
with the above safety precaution.
The appliance is supplied with a 13amp plug
fitted. In the event of having to change the fuse
in the plug supplied, a 13amp ASTA approved
(BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow ..............................- Earth
SHOWER
BATH
SINK TOILET
BIDET
WASHING
MACHINE
DISHWASHER
RAINWATER
'RUN-OFF'
SURFACE WATER
DRAINS & SEWERS
UNTREATED
DISCHARGE
RIVER
FOUL DRAIN
FOUL SEWERS
SEWAGE
TREATMENT
WORKS
RIVER
TREATED
DISCHARGE
Blue ....................................................- Neutral
Brown..................................................- Live
The wire coloured green and yellow must be
connected to the terminal marked with the
letter «E» or by the earth symbol
or
coloured green and yellow.
The wire coloured blue must be connected to
the terminal marked «N» or coloured black.
The wire coloured brown must be connected to
the terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp
must be secure over the outer sheath
Attention!
A cut off plug inserted into a 13 amp socket
is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
Attention!
Should the appliance power supply cable
need to be replaced, this MUST be carried
out by our Service Centre.
NOTE
Please ensure that when the appliance is
installed it is easily accessible for the engineer
in the event of a breakdown.
GREEN &YELLOW
BROWN
CORD CLAMP
BLUE
13
A
E
N
L
132966550.qxd 28/02/2008 13.56 Pagina 34