180SS-UK-5XX / 180SS-UK-5CD
©
TrickleStar
TRIMMER THRESHOLD
The “Trimmer”, adjusts the Threshold at which the peripheral
devices switch On/Off. The Trimmer Threshold is the power level
(Watts) of the “Control” device at which the product will switch
On/Off the devices connected to the Switched Outlets.
INSTALLATION REQUIRMENTS
Power Connections
The Product should only be plugged into an earthed outlet.
All connected devices should be plugged directly into the Product.
Using any extension cord in conjunction with the Product will void
all warranties.
Phone/Fax/Modem /Network Connections
Selected models come with phone/fax/data/ coaxial surge
protection. Instead of running a connection directly from your
phone/fax/computer to the wall jack, you must pass the connection
through the protected jacks on the product.
Connect your phone/fax/computer line from your wall outlet to the
“In” jack on the Product. Connect a phone cord or network cord
into the “Out” jack on the product, and connect the other end of the
phone cord to the phone/fax/network jack of the device you want to
protect.
If you fail to connect the phone/fax/data/coaxial protection, the
Connected Device Warranty will not cover your connected devices.
Most modem damage can be prevented if you take the time to
connect the phone/fax/data protection.
If you have multiple devices that utilize the same phone line you
may daisy chain them from the surge protector, but only using the
phone/fax/data protection.
Coaxial Cable Connections
Selected models come with coaxial cable surge protection. Instead
of
running
a
connection
directly
from
your
DSS
receiver/TV/VCR/cable box to the wall jack, you must pass the
connection through the protected aerial / coaxial connectors on
your Product.
Connect your incoming cable/antenna/DSS line to the “Input”
connector on the surge protector. Connect a coaxial cable into the
“Output” connector on the product, and then connect the other end
of the aerial / coaxial cable to the “Input ” connector of the device
you want to protect.
If you fail to use the aerial / coaxial cable protection, the
Connected Device Warranty will not cover your connected devices.
Most TV/VCR damage can be prevented if you take the time to
connect coaxial cable protection.
If you have multiple devices that utilize the same cable/antenna
line, you may daisy chain them from the surge protector, but only
using the coaxial cable protection.
LED Indication
The “Surge” light should be green when the powered. If this LED
goes red at any time it means that the Product was sacrificed to
protect your devices and should be replaced.
All connected devices should be plugged directly into your Product
- using any extension cord in conjunction with a Product will void
all TrickleStar warranties.
ELECTRICAL
AND
ENVIRONMENTAL
SPECIFICATIONS
FOR INDOOR USE ONLY
Voltage
250 VAC +/- 10% 50Hz
Outlets
1 Control Outlet
1 Always On Outlet
3 Switched Outlets
Power Rating
13A
Adjustable Threshold Range
20-55W (Power Factor 1)
Surge Protection
3672 Joules
Circuit Breaker Protection
13A
Power “In” cord
1.8 meters
Operating Temp
0° to 40°C
Storage Temp
-20ºC to +60ºC
Humidity
5 to 90% N/C
APPROVALS
ELECTRICAL & SAFETY
OTHER
CE
KEMA
2002/95/EG (RoHs)
2002/96/EC (WEEE)
PRODUCT WARRANTY
TrickleStar warrants to the original purchaser of the TrickleStar
Product for
ʻ
Product Lifetime
ʼ
, that the Product shall be free of
defects in design, assembly, material, or workmanship, and will
repair or replace, at its option, any defective product free of
charge.
The engineered
ʻ
Product Lifetime
ʼ
of this product is 10 years from
the date of production.
CONNECTED DEVICE WARRANTY
TrickleStar will repair or replace, at its option, any devices which
are damaged by a transient voltage surge/spike or lightning strike,
(an “Occurrence”), while properly connected through the
TrickleStar Product to a properly wired AC power line with
protective earth. If applicable; the telephone line, and/or network
line must be properly connected and installed, and the coaxial
cable line must also be properly connected and installed, as
determined by TrickleStar at its sole discretion.
Important
: If you are using a Product that does not have phone,
network, or coaxial protection the warranty is null and void if a
power disturbance damages your devices through the phone,
network, or coaxial lines. You are only covered if the disturbance
entered through the AC lines.
This Connected Device Warranty is a Limited Warranty, subject to
the limitations and exclusions set forth herein. TrickleStar will
repair or replace the damaged connected devices, at TrickleStar
ʼ
s
option, an amount equal to the fair market value of the damaged