16
Detail Programming Setup Values Continued
Active Keypad:
When enabled as an active keypad, this option allows transmission of touch tones from the
keypad after the initial call has been answered. This allows navigating a PBX or special
answering machine. It may also be abused if dial tone is ever restored without a
disconnect signal. This may give the visitor the ability to dial any number they wish into
what might be an open phone line with dial tone.
Keypad Beeps:
Normally keypad beeps are enabled. This gives a audio feedback of a key down stroke on the
keypad. It can be disabled for quiet areas that find it annoying such as a hospital zone
or even a front gate in a quiet community. Directory browsing is always quiet.
Tamper Alarm:
Normally enabled to use as a means to dissuade visitors from hacking an entry code at the
keypad. When enabled it will disable the unit for a preset time after three failed
attempts to discover a useful entry code. The lock out time is set via the Alarm Timer.
Note: These enables are broken down into "Y" or "N" values when viewed via the display or
remotely accessed via a Modem.
Operational Enables-4: (Defaults to 2)
Command to set: 4n
Where "n" is the selection of modes enabled.
n=0 Disable Auto Site Id Message, Disable Entry Message, Non-Muted Site Id Message
n=1 Enable Auto Site Id Message, Disable Entry Message, Non-Muted Site Id Message
n=2 Disable Auto Site Id Message, Enable Entry Message, Non-Muted Site Id Message
n=3 Enable Auto Site Id Message, Enable Entry Message, Non-Muted Site Id Message
n=4 Disable Auto Site Id Message, Disable Entry Message, Muted Site Id Message
n=5 Enable Auto Site Id Message, Disable Entry Message, Muted Site Id Message
n=6 Disable Auto Site Id Message, Enable Entry Message, Muted Site Id Message
n=7 Enable Auto Site Id Message, Enable Entry Message, Muted Site Id Message
Auto Site Id Message:
When enabled causes the unit to transmit all site identification information when the unit
has detected this distress call has been answered. This mode is usually found in the one
button dialers used in emergency situations such as a parking garage.
Entry Message:
This message is voiced to the visitor when entry has been granted because sometimes the
walk through gate or portal may not be obviously or visibly unlocked.
Muted Site Id Message:
This option determines if the person near the unit loud speaker is allowed to hear the
Site Identification while it is auto transmitted or has been remotely requested.
Note: These enables are broken down into "Y" or "N" values when viewed via the display or
remotely accessed via a Modem.
Viewing System Setup:
Command to Issue: *#0
Displays all setup parameters if a display exists.
Use the "*" key to scroll down the entire list.
Viewing System Configuration:
Command to Issue: *#1
Displays all database parameters if a display exists.
Use the "*" key to scroll down the entire list.
Summary of Contents for Uni-2010