5
1.5.
Purpose of contacts
Contact
Purpose
+E
+12 V power supply terminal
COM
General terminal
CLK
Synchronisation signal terminal
DATA
Data signal terminal
IN1
1st input terminal (type NC)
OUT1
1st output terminal (type OC)
IN2
2nd input terminal (type NC)
COM
General terminal
MCI
MCI data bus terminal
1.6.
Light indication
Light indication
Status
Description
Network
denotes connection with
the GSM network status
Green flashing
Connecting to the GSM network
Green light
Communicator is connected to the GSM network
Yellow flashing
The amount of yellow flashes denotes GSM connection
strength
Yellow light
A message is being sent
Data
denotes data
exchange
OFF
No messages or problems
Red flashing
SIM card problem
Red flashing intensely
Incorrect communicator settings
Green flashing
Data is being received
Green light
Unsent messages in memory
Red light
Problem with message sending
Power
denotes power supply
status, microprocessor
operation and
programming mode.
Green flashing
Power supply and microprocessor are in operation,
voltage is regular
Yellow flashing
Insufficient power supply voltage (below 11.5 V),
microprocessor is in operation
Green and yellow flashing
in turns
Programming mode
2.
Communicator installation
2.1.
Installation procedures
Action
Notes
1.
Set
communicator
operation
parameters.
Refer to information laid out in section
Setting operation
parameters
.
For example, to receive all messages via one channel, e.g. via GPRS,
it is enough to:
see
G10config
Main
window. Enter communicator (object)
identification number into the field
Object ID
and
PING
signal and
Test
message sending periods into fields
GPRS
PING time
and
Test time
;
see
G10config
GPRS
window. Select the GPRS transmission
channel in the list
GPRS
, enter static IP address of the
monitoring station and the port number in the fields
IP
address
and
Port
, enter the access point name (APN) of the
GPRS network in which the SIM card, that is inserted into
the communicator, operates in the field
APN
.
Note:
Enter
DNS
value if server IP name is indicated instead of
the IP address.
Indicate message encryption key in the field
Encryption key
if sent messages are encrypted. It must match the IP