settings group
•
Object ID
–
if the events will be sent to the CMS (Central Monitoring Station), enter the account number provided by the
CMS (4 characters hexadecimal number, 0-9, A-F.
Do not use FFFE, FFFF Object ID
).
•
Module ID
- 10-digit communicator ID used to identify the communicator at the receiver.
•
Use security panel account ID
–
if the checkbox is selected, the communicator will send events with the account ID
entered in the panel instead of the value set in the
Object ID
field.
•
Wait acknowledgment from CMS
–
if the checkbox is selected, after sending each event the communicator will wait for
acknowledgment from the IP receiver indicating that it has successfully received the event message. If the communicator
will not receive the acknowledgement signal, it will not form the end-of-communication (kiss-off) signal. After not
receiving the kiss-off, the control panel landline dialer will repeatedly transmit the event message.
•
Security panel model
–
enable/disable DTMF landline interface on the communicator.
•
First HSK tone/ Second HSK tone/ Third HSK tone/ Fourth HSK tone
-
“handshake” control panel tone
. (It is
recommended to leave the default settings.).
•
Dial tone frequency
–
frequency in which the
G16T
communicates with the control panel landline dialer.
•
Time set
–
select which server to use for time synchronization.
“Access” settings
group
•
Administrator code
–
allows you to access all configuration fields (default code - 123456).
•
Installer code
–
allows to change only those fields that are allowed by the administrator (default code - 654321).
•
Only an administrator can restore
–
if this box is selected, factory settings can be restored only by entering the
administrator code.
•
Allow installer to change
–
the administrator can specify which settings the installer can change.
“
CMS
settings”
tab
The communicator sends events to the monitoring station via cellular internet (IP).
Events can be sent through several communication channels. The primary and parallel communication channels can operate
simultaneously, this way the communicator can send events to two receivers at the same time. Backup channels can be assigned
for both primary and parallel channels, which will be used when the connection via the primary or parallel channel is interrupted.
Communication is encoded and password protected. A TRIKDIS receiver is required for receiving and sending event information
to the monitoring software: