Cellular communicator G16T_LTE-M 
 

 

For  connection  over  IP 

  software  receiver  IPcom  Windows/Linux,  hardware  IP/SMS  receiver  RL14  or  multichannel 

receiver RM14.  

 

“Primary channel” settings group

  

 

Communication type

 

 select which connection method to monitoring station receiver will be used (IP).  

 

Protocol 

 select in which coding the events should be sent: 

TRK8 

(to TRIKDIS receivers),

 SIA DC-09 

(to receivers, which 

receive events encoded in SIA DC-09 format).  

 

Encryption key

 

 16-digit message encryption key. 

The key written to the communicator must match the receiver’s key. 

 

 

Domain or IP

 

 enter the domain or IP address of the receiver.  

 

Port 

 enter the network port number of the receiver.  

 

TCP or UDP 

 select in which protocol (TCP or UDP) the events should be sent.  

“Primary channel Backup” settings group 

 

Enable the backup channel mode to send events via backup channel if connection via primary channel is lost. Backup channel 
settings are same as described above.  

“Parallel channel” settings group

  

Through this channel events are transmitted in parallel with the primary channel. When the second channel is enabled, events 
can be sent simultaneously to two receivers (e.g., local and centralized monitoring stations). Parallel channel settings are the 
same as described above.  

“Settings” tab

 

 

 

“Settings” 

settings group  

 

Test period

 - TEST event period for testing the connection. Test events are sent as Contact ID messages and forwarded 

to the monitoring software.  

 

IP ping period

 

 period for sending internal PING heartbeats. These messages are only sent via IP channel. The receiver 

will not forward PING messages to the monitoring software to avoid overloading it. Notifications will only be sent to the 
monitoring software if the receiver fails to receive PING messages from the device within the set time.  

By default, the receiver will send a 

Connection lost” 

notification to the monitoring software if the PING message is not 

received over a time period three times longer than set in the communicator.  E.g. if the PING period is set for 3 minutes, 
the receiver will send the 

“Connection lost”

 notification if PING message is not received within 9 minutes.  

PING  heartbeats  keep  the  active  communication  session  between  the  device  and  the  receiver.  An  active  session  is 
required to be able to remotely configure and control the communicator. We recommend setting the PING period for no 
more than 5 minutes.  

 

Backup reporting  after 

-  indicates  the number of unsuccessful  attempts  to send  the  message via  Primary  channel. If 

device fails to transmit specified number of times, it will connect to transmit the messages via Backup channel.  

 

Return from backup after

 - time after which 

G16T 

will attempt to reconnect and transmit messages via Primary channel. 

 

 

Summary of Contents for G16T

Page 1: ...www trikdis lt UAB Trikdis Draugyst s str 17 LT 51229 Kaunas Lithuania 370 37 408 040 info trikdis lt Cellular communicator G16T Installation manual January 2021...

Page 2: ...TING IO 8 EXPANSION MODULE 13 3 7 SCHEMATIC FOR CONNECTING THE W485 WIFI MODULE 14 3 8 SCHEMATIC FOR CONNECTING THE E485 ETHERNET MODULE 14 3 9 TURN ON THE COMMUNICATOR 14 PROGRAMMING THE CONTROL PANE...

Page 3: ...d Approvals These listings and approvals apply only to the module specified in this document In some cases listing may be in process FCC Statement This equipment complies with FCC rules Part 15 FCC re...

Page 4: ...s malfunctions if the communicator is installed or used not according to its manual the communicator s malfunctions if the cause is a malfunction or loss of GSM GPRS Internet connectivity or malfuncti...

Page 5: ...09 receivers Connection supervision by polling to IP receiver every 30 seconds or by user defined period Backup channel that will be used if connection with the primary channel is lost With parallel...

Page 6: ...rotocols TRK8 DC 09_2007 DC 09_2012 Message encryption AES 128 Changing settings With TrikdisConfig computer program remotely or locally via USB Mini B port Operating environment Temperature from 14 F...

Page 7: ...ransferred to from communicator POWER Off Power supply is off or disconnected Green solid Power supply is on with sufficient voltage Yellow solid Power supply voltage is insufficient 11 5V Green solid...

Page 8: ...with TrikdisConfig software 1 Download configuration software TrikdisConfig from www trikdis com type TrikdisConfig in the search field and install it 2 Open the casing of the G16T with a flat head sc...

Page 9: ...SIM card PIN code 4 Change APN name APN can be found on the website of the SIM card operator internet is universal and works in many operator networks After finishing configuration click the button Wr...

Page 10: ...for your event messages TRK8 to TRIKDIS receivers DC 09_2007 or DC 09_2012 to universal receivers 4 TRK encryption key enter the encryption key that is set in the receiver 5 Domain or IP enter the re...

Page 11: ...et it up correctly so that the panel would send the events Alarm panel setup is described in chapter 4 Programming the control panel Installation and wiring 1 Remove the top cover and pull out the con...

Page 12: ...ls that can be set to an OUT PGM operating mode The outputs can control three areas of the security system Area control settings are made in the Protegus app The communicator has 3 universal input out...

Page 13: ...expander With relay contacts you can control turn on off various electronic appliances The I O terminal of the communicator must be set to an output OUT mode If more inputs or outputs need to be conn...

Page 14: ...nto the communicator G16T for E485 to work To start the communicator turn on the security control panel s power supply This LED indication on the G16T communicator must show POWER LED illuminates gree...

Page 15: ...must be set to 5 50 delay for sending burglary alarm events optional Default value is 2 0 With it the event message transmission will be delayed for 30 seconds If you want the message to be sent imme...

Page 16: ...and the packaging sticker After entering press Next Important The control panel zone to which the G16T output OUT is connected to has to be set to keyswitch mode Follow the instructions below if the s...

Page 17: ...h zone You can also change the duration of the pulse interval if it is required for the connected control panel 5 For additional security you can select Use Application password for ARM DISARM Then af...

Page 18: ...number Status Operating condition Device Device type G16T should be shown SN Device serial number BL Browser version FW Device firmware version HW Device hardware version Status Connection to program...

Page 19: ...Fourth HSK tone handshake control panel tone It is recommended to leave the default settings Dial tone frequency frequency in which the G16T communicates with the control panel landline dialer Time s...

Page 20: ...bed above Settings tab Settings settings group Test period TEST event period for testing the connection Test events are sent as Contact ID messages and forwarded to the monitoring software IP ping per...

Page 21: ...ection will be used for sending events via IP channel to the monitoring station receiver or to Protegus ensure that mobile data service is enabled SIM card settings group SIM card PIN enter the SIM ca...

Page 22: ...or Restore CID enter the event code or leave the default value Upon entering the event the event code will be sent to Protegus and CMS SIA enter the event code or leave the default value Upon enterin...

Page 23: ...on receiver and to Protegus app Contact ID event code Enable allow message transmission when the input is triggered E R choose what type of event will be sent when input is triggered Event or Restore...

Page 24: ...Fi network password In the table you can assign Contact ID SIA 4 2 event and restore codes to the RS485 data bus fault event When connection between the W485 and G16T is disrupted or re established th...

Page 25: ...vent messages sent by the device After turning off an internal event in this window it will not be sent irrespective of other settings COMMUNICATION message about connection error between the control...

Page 26: ...trigger them and make sure you receive the correct event 4 To test the communicator outputs activate them remotely and check their operation 5 If the security control panel will be controlled remotely...

Page 27: ...www trikdis com 27 January 2021 Cellular communicator G16T_LTE M 6 Wait for the update to complete...

Reviews: