Cellular communicator G16T_LTE-M 
 

 

Safety requirements  

The communicator must be installed and maintained by qualified personnel. 

Before  installation,  please  read this  manual  carefully  to avoid  mistakes  that  may  cause  malfunction  or  even damage  to  the 
equipment. 

Changes, modifications or repairs not authorized by the manufacturer will void your rights under the warranty. 

This unit should be serviced by a qualified technician once a year. 

Do not use the device with medical devices or where it may interfere with other devices and cause any potential danger. 

Do not expose the device to high humidity, chemical environment or mechanical impact.  

Clean the device with a dry cloth. Do not clean it with chemicals, detergents. 

Do not use the device in a hazardous environment. Do not store or install the device in overheated, dusty, wet, or overcooled 
locations.  

Keep the device dry. Any liquid, ie rain, moisture, can destroy or damage the internal circuits. 

The  device  is  mounted  in  areas  with  limited  access.  Any  system  repair  should  only  be  done  by  qualified,  safety-conscious 
personnel. Do not disassemble or reinstall the device. Do not try to repair it yourself. 

The mains power must be disconnected before any installation or adjustment work state. Installation or maintenance of the 
device should not be performed during stormy conditions. 

Blown fuses or any other component of the device must not be replaced by the user. 

Handle with care. Do not vibrate or shake it violently. 

Act in accordance with local regulations and do not dispose of your old alarm system or its components with other 
household waste. 

 

Agency Listings and Approvals 

These listings and approvals apply only to the module specified in this document, In some cases, listing may be in process.  

 

FCC Statement.  

This equipment complies with FCC rules Part 15, FCC registration No. XMR201707BG96 and operation is subject to the 
following conditions:  

(1)

 

This device may not cause harmful interference, and  

(2)

 

This device must accept any interference received.  

 

 UL standards 

 Pending.  

Limited Liability 

The user agrees that despite the Device could reduce the risk of fire, theft, burglary or other dangers, it does not guarantee 
against such events. Trikdis LTD will not take any responsibility regarding personal, property or revenue loss while using Device 
responsibility according to local laws does not exceed the value of the purchased system. TRIKDIS LTD is not affiliated with 
GSM operators providing cellular services, therefore is not responsible for network services, coverage or its operation.  

Manufacturer Warranty

 

The communicator is given a 24-month warranty effective from the date of sale-purchase. For the duration of the warranty 
period, free repairs are guaranteed for faults caused by the manufacturer.  

The warranty is valid if the communicator was installed by qualified personnel following the instructions in this document 
and the applicable regulations for installing electrical equipment and operated following the instructions in this document 
and the applicable regulations for safe operation of electrical equipment.  

The  communicator 

must  be submitted  for repairs  in  the manufacturer‘s packaging  along  with  a defect  report  stating  the 

nature of the malfunction.  

Once the warranty has expired, the communicator

‘s technical maintenance and repairs are performed at the buyer‘s expense. 

 

The warranty can be terminated prematurely if:  

 

Unauthorized personnel repaired or tried to repair the communicator;  

Summary of Contents for G16T

Page 1: ...www trikdis lt UAB Trikdis Draugyst s str 17 LT 51229 Kaunas Lithuania 370 37 408 040 info trikdis lt Cellular communicator G16T Installation manual January 2021...

Page 2: ...TING IO 8 EXPANSION MODULE 13 3 7 SCHEMATIC FOR CONNECTING THE W485 WIFI MODULE 14 3 8 SCHEMATIC FOR CONNECTING THE E485 ETHERNET MODULE 14 3 9 TURN ON THE COMMUNICATOR 14 PROGRAMMING THE CONTROL PANE...

Page 3: ...d Approvals These listings and approvals apply only to the module specified in this document In some cases listing may be in process FCC Statement This equipment complies with FCC rules Part 15 FCC re...

Page 4: ...s malfunctions if the communicator is installed or used not according to its manual the communicator s malfunctions if the cause is a malfunction or loss of GSM GPRS Internet connectivity or malfuncti...

Page 5: ...09 receivers Connection supervision by polling to IP receiver every 30 seconds or by user defined period Backup channel that will be used if connection with the primary channel is lost With parallel...

Page 6: ...rotocols TRK8 DC 09_2007 DC 09_2012 Message encryption AES 128 Changing settings With TrikdisConfig computer program remotely or locally via USB Mini B port Operating environment Temperature from 14 F...

Page 7: ...ransferred to from communicator POWER Off Power supply is off or disconnected Green solid Power supply is on with sufficient voltage Yellow solid Power supply voltage is insufficient 11 5V Green solid...

Page 8: ...with TrikdisConfig software 1 Download configuration software TrikdisConfig from www trikdis com type TrikdisConfig in the search field and install it 2 Open the casing of the G16T with a flat head sc...

Page 9: ...SIM card PIN code 4 Change APN name APN can be found on the website of the SIM card operator internet is universal and works in many operator networks After finishing configuration click the button Wr...

Page 10: ...for your event messages TRK8 to TRIKDIS receivers DC 09_2007 or DC 09_2012 to universal receivers 4 TRK encryption key enter the encryption key that is set in the receiver 5 Domain or IP enter the re...

Page 11: ...et it up correctly so that the panel would send the events Alarm panel setup is described in chapter 4 Programming the control panel Installation and wiring 1 Remove the top cover and pull out the con...

Page 12: ...ls that can be set to an OUT PGM operating mode The outputs can control three areas of the security system Area control settings are made in the Protegus app The communicator has 3 universal input out...

Page 13: ...expander With relay contacts you can control turn on off various electronic appliances The I O terminal of the communicator must be set to an output OUT mode If more inputs or outputs need to be conn...

Page 14: ...nto the communicator G16T for E485 to work To start the communicator turn on the security control panel s power supply This LED indication on the G16T communicator must show POWER LED illuminates gree...

Page 15: ...must be set to 5 50 delay for sending burglary alarm events optional Default value is 2 0 With it the event message transmission will be delayed for 30 seconds If you want the message to be sent imme...

Page 16: ...and the packaging sticker After entering press Next Important The control panel zone to which the G16T output OUT is connected to has to be set to keyswitch mode Follow the instructions below if the s...

Page 17: ...h zone You can also change the duration of the pulse interval if it is required for the connected control panel 5 For additional security you can select Use Application password for ARM DISARM Then af...

Page 18: ...number Status Operating condition Device Device type G16T should be shown SN Device serial number BL Browser version FW Device firmware version HW Device hardware version Status Connection to program...

Page 19: ...Fourth HSK tone handshake control panel tone It is recommended to leave the default settings Dial tone frequency frequency in which the G16T communicates with the control panel landline dialer Time s...

Page 20: ...bed above Settings tab Settings settings group Test period TEST event period for testing the connection Test events are sent as Contact ID messages and forwarded to the monitoring software IP ping per...

Page 21: ...ection will be used for sending events via IP channel to the monitoring station receiver or to Protegus ensure that mobile data service is enabled SIM card settings group SIM card PIN enter the SIM ca...

Page 22: ...or Restore CID enter the event code or leave the default value Upon entering the event the event code will be sent to Protegus and CMS SIA enter the event code or leave the default value Upon enterin...

Page 23: ...on receiver and to Protegus app Contact ID event code Enable allow message transmission when the input is triggered E R choose what type of event will be sent when input is triggered Event or Restore...

Page 24: ...Fi network password In the table you can assign Contact ID SIA 4 2 event and restore codes to the RS485 data bus fault event When connection between the W485 and G16T is disrupted or re established th...

Page 25: ...vent messages sent by the device After turning off an internal event in this window it will not be sent irrespective of other settings COMMUNICATION message about connection error between the control...

Page 26: ...trigger them and make sure you receive the correct event 4 To test the communicator outputs activate them remotely and check their operation 5 If the security control panel will be controlled remotely...

Page 27: ...www trikdis com 27 January 2021 Cellular communicator G16T_LTE M 6 Wait for the update to complete...

Reviews: