Configuration and control by SMS messages 

Commands sent by SMS message 

Item 

No. 

Command 

Content 

Note 

RESET 

 

Controller GV15 reset 
E. g.: 123456 RESET 

INFO 

 

Inquiry about controller status. 
E. g.: 123456 INFO 

PSW 

New password 

Controller GV15 password changing. 
E. g.: 123456 PSW 654321 

SETC 

 
ALL 
LIST 
DISABLE 

Permission for dial control: 
All callers (default) 
Only those on User and Administrator lists; 
Only those on Administrator list. 
E. g.: 123456 SETC LIST 

SETD 

 
ON 
OFF 

Permission for DTMF code control: 
Control by DTMF codes available; 
Control by DTMF codes impossible (default). 
E. g.: 123456 SETD ON 

SETI 

 
NC 
NO 

Setting input IN1, IN2 type: 
Normally Closed; 
Normally Open; 
E. g.: 123456 SETI NO 

SETO1 

 
00 
05 

1st relay operation: 
Switching level mode; 
Specified impulse duration from 1 to 60 seconds 
E. g.: 123456 SETO1 05 

SETO2 

 
00 
05 

2nd relay operation: 
Switching level mode; 
Specified impulse duration from 1 to 60 seconds 
E. g.: 123456 SETO2 05 

SETT 

 
00 
30 
 

Test message sending period: 
Do not send test message; 
Send test message in specified period (1-30 days); 
E. g.: 123456 SETT 30 

SETH 

 
00 
10 
 

Answering phone call: 
Reject without answering (default); 
Answer a phone call and hold for specified time in seconds (1-10 sec.); 
E. g.: 123456 SETH 05 

10 

SETL 

 
ENG 
LIT 
RUS 

Setting the communication language: 
English (default); 
Lithuanian; 
Russian; 
E. g.: 123456 ENG 

11 

SETAP 

 
APNR1:+xxxxxxxxx 
APNR2:+xxxxxxxxx 
APNR3:+xxxxxxxxx 
APNR4:+xxxxxxxxx 
APNR5:+xxxxxxxxx 
APNR6:+xxxxxxxxx 
APNR7:+xxxxxxxxx 
APNR8:+xxxxxxxxx 
 

Entering the administrator phone numbers (up to 16 digits): 
1st phone number; 
2nd phone number; 
3rd phone number; 
4th phone number; 
5th phone number; 
6th phone number; 
7th phone number; 
8th phone number; 
E. g.: 123456 SETAP APNR1:+370654321 

Summary of Contents for GV15

Page 1: ...Draugyst s g 17 LT 51229 Kaunas E mail info trikdis lt www trikdis com...

Page 2: ...sive periodic test message SMS message distribution to administrators based on controller event types All operation parameter setting by SMS messages SMS commands to receive the lists of administrator...

Page 3: ...saction i e invoice or cash receipt issue date Warranty may be terminated prematurely in the following cases The controller was repaired or attempted to repair by an unauthorized person The controller...

Page 4: ...hanging Access and SMS password 12 6 3 2 Restore of default settings 12 INPUT PARAMETERS 13 6 4 1 Input type selection 13 6 4 2 Message sending after actuation restoration 13 RELAY PARAMETERS 13 6 5 1...

Page 5: ...mand commutates relays until the next control command e g until the next call Memory Up to 8 administrator names and their phone numbers Up to 1000 user names and their phone numbers Inputs 2 IN1 and...

Page 6: ...nating supply voltage terminal IN1 1st input IN1 terminal COM Common ground terminal for inputs IN1 and IN2 IN2 2nd input IN1 terminal NO1 1st relay NO terminal C1 1st relay common terminal NC1 1st re...

Page 7: ...supply voltage or no power supply Lighting Normal power supply Trouble Off Non troubles Lighting for 5 sec N flashes 1 flash Insufficient supply voltage 2 flashes No SIM card 3 flashes PIN code error...

Page 8: ...oller power supply and automatics control circuits to the controller contacts according to the scheme below 5 Turn on power supply of the whole system 6 Wait for the controller to start operating Moni...

Page 9: ...ring diagrams 5 Wiring diagrams Inputs connection The controller contains two input terminals IN1 and IN2 for connection of sensor circuits For setting the input connection type and reports on activat...

Page 10: ...n a new window for programming General software operation 1 To read the parameters entered in the controller click the button Read F4 and enter Access and SMS password in the pop up window Window requ...

Page 11: ...gram control actions Write F5 Write the controller parameters into the module Help Auxiliary information about the module and software Open F8 Open the saved file of parameters Save F9 Save the file o...

Page 12: ...the password and not to prompt entering it when writing and reading the parameters mark the checkbox next to Remember Password 6 3 2 Restore of default settings To reset the controller default setting...

Page 13: ...once controller receives control command Pulse duration 1 60 seconds Relay operation modes are selected in the program menu System settings for the first relay in Output 1 NC and NO options field for...

Page 14: ...tors User list parameters To form a list of users authorized for dial control of the first relay go to the program menu User List The dial control mode Users and Administrators must be selected User d...

Page 15: ...Administrator parameters Name Description Administrator name Administrator name Phone No Administrator phone number must be entered in international format using prefix Relay 1 Dial control of Relay 1...

Page 16: ...confirmation Reply SMS texts Module output messages Name Description Module terminals Names of output to be reported by message SMS texts on event SMS message texts after output mode changed SMS texts...

Page 17: ...ation and control by SMS messages Controller GV15 parameters may be set and changed by sending SMS messages from a phone number which is on Administrator list In case there are not any entered adminis...

Page 18: ...itching level mode Specified impulse duration from 1 to 60 seconds E g 123456 SETO1 05 8 SETO2 00 05 2nd relay operation Switching level mode Specified impulse duration from 1 to 60 seconds E g 123456...

Page 19: ...r s name entering 1 28 symbols 1st administrator name 2nd administrator name 3rd administrator name 4th administrator name 5th administrator name 6th administrator name 7th administrator name 8th admi...

Page 20: ...h phone numbers and administrator names enlisted will be generated and sent E g 123456 LISTA 22 LISTU User list request SMS messages with phone numbers and user names enlisted will be generated and se...

Page 21: ...en OUT ON OFF Relay status ON OFF Used Phone Admin x 8 x phone numbers out of 8 possible entered User x 1000 Fatal ERROR x phone numbers out of 1000 possible entered Controller ignoring the phone numb...

Page 22: ...l in a phone keypad the end of command 3 The control command shall be accomplished when the controller having sent a tone signal of 0 5 sec duration will reject your phone call Note Your phone number...

Page 23: ...ON to enable the 1st relay 2 Await for confirmation of command execution if set by default in configuration Command OK command completed Wrong Password false password Wrong Command false command Wron...

Reviews: