Control panel SP231
System installation
©1997-2015 Trikdis
15
www.trikdis.com
5.2
Compatible modules
Product code
Bus
Purpose
Current
consumption
Trikdis PROTEGUS
SK232LED W/B
Y/G
2 partitions, 32 zone LED keyboard with touch-
sensitive keys, white or black glass surface
up to 150 mA
Trikdis PROTEGUS
SK130LED W/B
Y/G
16 zone LED keyboard with touch-sensitive keys,
white or black glass surface
up to 150 mA
Paradox K32+
Y/G
32 zone LED keyboard
up to 150 mA
Paradox K32LED
Y/G
32 zone LED keyboard
up to 150 mA
Paradox K10LEDV
Y/G
10 zone LED vertical keyboard
up to 100 mA
Paradox K10LEDH
Y/G
10 zone LED horizontal keyboard
up to 100 mA
Paradox K636
Y/G
10 zone LED keyboard
up to 100 mA
CZ8
Y/G
8 zone input expansion module
50 mA
W131
MCI
Interface with iButton key code reader
30 mA
T10R
MCI
Radio transmitter able to send control panel event
reports at VHF range radio frequencies
standby - 50 mA
sending - up to 1 A
E10C
MCI
Ethernet communicator able to send control panel
event reports via internet networks
standby - 60 mA
sending – up to
100 mA
G10D
MCI
GSM&GPRS communicator able to send control
panel event reports via GPRS and/or SMS.
standby - 60 mA
sending – up to
250 mA
CZ-DALLAS
1-wire
iButton key reader
up to 25 mA
DS18B20
DS18S20
1-wire
Temperature sensor Dallas. Measuring range from -
55°C to +125°C
1 µA
5.3
Connection of sensors
The control panel circuit board has eight terminals ZN1–ZN8 (inputs) for connection of sensor control circuits.
When using input expanders CZ8, the number of outputs can be increased up to 32. Regarding setting of every
input as a zone, i.e. assigning the zone attributes: circuit type (EOL, NC...), sensitivity to short-term circuit
events, zone function (“Delay”, “Instant”...) see 6.7 “Zone parameters”.
Normally closed
circuit (NC).
Normally open
circuit (NO).
Normally open circuit
with end of line resistor
(EOL, End of Line).
Normally closed circuit with end
of line resistor (EOL, End of
Line).
Normally closed circuit with end of line
resistor and tamper recognition (NC with
EOL & tamper recognition).
Normally closed circuit with tamper anti-masking
recognition (NC with tamper & anti-masking recognition).