Gebrüder TRILETY Ges.m.b.H.
MCK-M31 1.02
09/ 2018
* Optional equipment
Page
31
Note
:
The shut off plate must be under all circumstances inserted so that
no air is sucked in over this opening during the normal sweeping
operation. If this opening is not shut off, the suction efficiency while
sweeping is greatly diminished.
23. Open the locking system that locks the suction hose of the rear sweeping
unit on to the connection piece of the discharge flap of the hopper.
24. Remove the shut-off plate between the suction hose and the connection
piece and re-lock the suction hose on to the connection piece.
25. Turn off the rotating flashing beacon.
If the hand suction hose system is not be used for a longer period of time, it
should be dismounted and stored in a dark, dry place. This procedure will
extend the life of the hose.
1. Loosen the screws that lock the hose fixing strap on the connection piece
and disconnect the hose from the connection piece.
2. Unlock the locking system that hold the hand suction hose on the hopper
roof.
3. Remove the hand suction hose from the hopper roof.
4. Unhook the hand suction hose from the hose boom* and store the hand
suction hose in a darken room.
5. Ensure that the connection piece is closed using the shut-off plate.