e-ASK I/O Module Hints 

No response in any system 
element. No LED flash (LED 
is under enclosure cover). 

Verify power to the I/O module. 

Unexpected operations occurs 

Verify DIP switches are set to correct 
configuration setting. 

No response in any system 
element. LED flashing (LED is 
under enclosure cover). 

I/O module is detecting problem with 
communication network (CAN).  
Check that network is valid by 
confirming that other modules are 
plugged into network and that 
network terminating resistors are 
correct value and are installed. 

Problem Description 

Possible Solution 

Summary of Contents for 24324-03

Page 1: ...e ASK electronic Access Security Keyless entry CAN Multiplex System CAN Multiplex System Installation Instructions UM27 24324 03...

Page 2: ...pad 1 e FOB Operation and Features 2 Additional Features 2 Dome Porch Light Activation 2 e PAD Anti tamper Deactivating Feature 2 Teaching Keypad New Authority Access Codes 2 Assign New Access Codes 3...

Page 3: ...5 7 8 7 8 7 8 7 8 7 8 Access code Authority code Locking Doors With Keypad Press and hold down the 1 2 button for 1 2 seconds An access code is not needed to lock the doors Unlocking Doors With Keypad...

Page 4: ...eactivating Feature After repeated attempts to enter code 20 button presses without enabling the keypad enters an inactive mode that disables button for 1 minute This helps prevent access by entering...

Page 5: ...2 Enter the 5 digit authority code see page above Keypad will provide a long beep that will stop after you have defined an access number 3 Press and release any button This button corresponds to the a...

Page 6: ...nds The keypad will beep and the LEDs will flash 2 Enter authority code Keypad will provide a sustained beep 3 Press and hold 9 0 for 5 seconds A double beep plays a The receiver module is now in FOB...

Page 7: ...ntil fast LED flash This synchs the 2nd FOB transmitter 9 Repeat step 8 until all FOBs are synched up to 4 FOBs 10 Remove power and CAN from door module 11 Move DIP switches 4 6 to original position a...

Page 8: ...standard FOB or cargo FOB On Cargo FOB Off Standard FOB 2 button DIP Switch 8 The setting of DIP switch 8 defines the type of CAN protocol either RV C or SAE J1939 Fire truck and ambulance application...

Page 9: ...up input Black Right Header Connector Deutsch DT06 12SB currently 128B Terminal Deutsch 1062 16 1122 Wedgelock W128 currently 128 Wiring Assignments 1 Dome Light output 2 Antennae pin 3 CAN Low 4 Doo...

Page 10: ...sponse with button press Verify power to the I O module Verify that keypad cable is connected rest of system will function Access code is not recognized Verify that code has not been changed Reassign...

Page 11: ...are set to correct configuration setting No response in any system element LED flashing LED is under enclosure cover I O module is detecting problem with communication network CAN Check that network...

Page 12: ...UM27 24324 03 09 11 2...

Reviews: