Option 2 (if no CAN keypad is connected to network) 

1.  Remove power from door module. 
2.  Open up door module enclosure. 
3.  Move DIP switches 4-6 to the “ON” position. 
4.  Connect door module to CAN network. 
5.  Connect power to door module.  
6.  Wait 5 seconds. The  LED will come on solid and then continue to 

flash. 

7.  Press lock button of the first FOB for 2 seconds until LED pattern 

changes (fast flash), then release. This synchs the first FOB 
transmitter. 

8.  Press lock FOB button of 2nd FOB for 1 second, until fast LED 

flash. This synchs the 2nd FOB transmitter. 

9.  Repeat step 8 until all FOBs are synched (up to 4 FOBs). 
10.  Remove power and CAN from door module. 
11.  Move DIP switches 4-6 to original position and verify DIP switches 

1-3 are in proper position. 

12. Reassemble enclosure. 
13.  Reconnect power and CAN to module. 
14.  Verify that FOBs are synched to the door module and that range 

of RF transmission is acceptable. 

 

e-ASK CAN DIP Switch Configurations 

DIP Switches 1-3: 

The settings of DIP switches 1-3 define the CAN address of the 
module. Each door module must have a unique address. 

Dipswitch

 

Driver Door

 

Rear Left

 

Rear Right

 

1 Off 

Off Off 

2 Off 

On On 

3 Off 

Off On 

Front Right 

Off 

Off 

On 

Summary of Contents for 24324-03

Page 1: ...e ASK electronic Access Security Keyless entry CAN Multiplex System CAN Multiplex System Installation Instructions UM27 24324 03...

Page 2: ...pad 1 e FOB Operation and Features 2 Additional Features 2 Dome Porch Light Activation 2 e PAD Anti tamper Deactivating Feature 2 Teaching Keypad New Authority Access Codes 2 Assign New Access Codes 3...

Page 3: ...5 7 8 7 8 7 8 7 8 7 8 Access code Authority code Locking Doors With Keypad Press and hold down the 1 2 button for 1 2 seconds An access code is not needed to lock the doors Unlocking Doors With Keypad...

Page 4: ...eactivating Feature After repeated attempts to enter code 20 button presses without enabling the keypad enters an inactive mode that disables button for 1 minute This helps prevent access by entering...

Page 5: ...2 Enter the 5 digit authority code see page above Keypad will provide a long beep that will stop after you have defined an access number 3 Press and release any button This button corresponds to the a...

Page 6: ...nds The keypad will beep and the LEDs will flash 2 Enter authority code Keypad will provide a sustained beep 3 Press and hold 9 0 for 5 seconds A double beep plays a The receiver module is now in FOB...

Page 7: ...ntil fast LED flash This synchs the 2nd FOB transmitter 9 Repeat step 8 until all FOBs are synched up to 4 FOBs 10 Remove power and CAN from door module 11 Move DIP switches 4 6 to original position a...

Page 8: ...standard FOB or cargo FOB On Cargo FOB Off Standard FOB 2 button DIP Switch 8 The setting of DIP switch 8 defines the type of CAN protocol either RV C or SAE J1939 Fire truck and ambulance application...

Page 9: ...up input Black Right Header Connector Deutsch DT06 12SB currently 128B Terminal Deutsch 1062 16 1122 Wedgelock W128 currently 128 Wiring Assignments 1 Dome Light output 2 Antennae pin 3 CAN Low 4 Doo...

Page 10: ...sponse with button press Verify power to the I O module Verify that keypad cable is connected rest of system will function Access code is not recognized Verify that code has not been changed Reassign...

Page 11: ...are set to correct configuration setting No response in any system element LED flashing LED is under enclosure cover I O module is detecting problem with communication network CAN Check that network...

Page 12: ...UM27 24324 03 09 11 2...

Reviews: