Page 4 of 14
Part Number 8519184-0000 Rev: B
Figure 1
Connection Illustration
Convert 2 x 4 Configuration to a 1 x 8 or vice versa:
To convert either way, either connect or disconnect a jumper cable between the 2
nd
connector for
the SCSI A and SCSI B connectors at the rear of the enclosure (reference Figure’s 1and 4).
For a 1 x 8 configuration, install the a SCSI jumper cable between the second connectors for the
SCSI A and SCSI B connectors. The host is connected to SCSI A, while SCSI B is either
terminated or connected to the next device in the chain (reference Figure’s 1 and 4).
For a 2 x 4 configuration, disconnect the cables between SCSI A and SCSI B connectors and
either terminate the second connector for each of SCSI A and SCSI B, or connect them to the
next device in the chain, with a terminator at the end of the chain.