background image

Op

G

G

lobe Control Valve

Optimux customers should be aware that Optimux products might be used in numerous applications under a wide variety of industrial
service conditions. Although Optimux can (and often does) provide general guidelines, it cannot provide specific data and warnings
for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection,
installation, operation and maintenance of Optimux products. The purchaser/user should read and understand the Product Instruction
Manual (PIM) included with the product, and train its employees and contractors in the safe use of Optimux products in connection
with the specific application.

While the information and specifications presented in this literature are believed to be accurate, they are supplied for informative
purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained
herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because
Optimux is continually improving and upgrading its product design, the specifications, dimensions and information contained herein
are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact
TRIMTECK, LLC at any of its worldwide operations or offices.

For more information, contact:

FORM #  PIM0910

For more information about Trimteck and its products,
contact www.trimteck.com or call USA (954) 753-5545

TRIMTECK LLC
12461 NW 44th Street
Coral Springs, FL 33065
Phones: (954) 753-5545
Fax: (954) 753-5561 
info@trimteck.com 

Krytox 206 is a registered trademark of I.E. DuPont.
GP 406 is a registered trademark of Graphite Products Co.
Aeroshell Grease 7 is a registered trademark of Shell Oil Co.
Garlock Luball is a registered trademark of Garlock Inc.

Summary of Contents for Optimux OpGL

Page 1: ...shutoff easier to achieve Valve specifications are as follows Table 1 Specifications TABLE OF CONTENTS INTRODUCTION Scope of Manual pg 1 Description pg 1 Specifications pg 1 Safety Information pg 1 U...

Page 2: ...uator vertical above the body This is also important for cryogenic applications to keep the packing isolated from the flowing medium permitting the packing temperature to remain close to ambient tempe...

Page 3: ...the Assembly Disassembly section 1 Inspect end flanges and bonnet for signs of gasket leakage Tighten flange and bonnet bolting if required See Table 4 2 Check the pressure balance sleeve metal bellow...

Page 4: ...ep 2 If valve is air to open apply air under piston to raise the plug off the seat before taking the valve apart 2 Take out the bonnet flange bolting which will allow for removal of the actuator bonne...

Page 5: ...the top guide to enter Different spacer lengths allow a wide variety of packing configurations such as twin seal and vacuum pressure packing WARNING Valves with extended bonnets or metal bellows seals...

Page 6: ...d up against the finger tight body with such force that it will not be possible to wriggle the flange If improper seating occurred the bonnet flange can be wriggled with light hand force If this occur...

Page 7: ...positioned correctly between the bonnet and seat ring 2 Loosen the stem clamp 3 Take out the packing box bolting and yoke clamps 4 Completely unscrew the actuator off of the plug and bonnet without r...

Page 8: ...time until it is in place Replace the stem bellows and the stem clamp 7 Reinstall the gasket and adjusting screw using a new adjusting screw gasket The adjusting screw should be tightened only to the...

Page 9: ...points to the closed position 13 Reconnect the actuator positioner tubing supply and signal lines AIR ACTION REVERSAL Air to Open To switch the air action from air to close to air to open continue as...

Page 10: ...No 88 Yoke Clamp Item No 76 Packing Spacer s Item Nos 94 99 Bonnet Item No 40 Bonnet Flange Item No 70 Anti Extrusion Spacer Item No 93 Adjusting Screw Gasket Item No 248 Spring Button Item No 227 Ac...

Page 11: ...Square Packing w Lubricator Fitting Twin Square Packing w Lantern Ring Braided Wiper Rings 2 Vacuum Seal V packing Vacuum Seal Twin V packing w Lantern Ring Fugitive Emissions Packing PTG PT PTXT Liv...

Page 12: ...12 OpGL Globe Control Valve O S O S Figure 3 Air action Configurations Air to Open Air to Close...

Page 13: ...em No 114 Bonnet Flange Stud Item No 108 Bonnet Flange Item No 70 Figure 4 Exploded View Body Assembly NOTE Item numbers correspond directly to the valve s bill of material Refer to it for specific pa...

Page 14: ...Screw Gasket Item No 248 Cylinder Item No 202 Serial Plate Item No 252 Stem Clamp Item No 249 Stem Clamp Bolt Item No 240 Spring Button Item No 227 Spring Item No 229 Actuator Stem Lock Nut Item No 3...

Page 15: ...service conditions and contact factory 5 Incorrectly adjusted plug 5 Refer to steps 8 10 of Reassembling the Body section for correct plug adjustment 6 Improper flow direction 6 Refer to original spec...

Page 16: ...ly and should not be considered certified or as a guarantee of satisfactory results by reliance thereon Nothing contained herein is to be construed as a warranty or guarantee express or implied regard...