22
Portrait installation:
Standard short cable length
(Note: One end of the single row needs to be extended)
Landscape installation:
Standard long cable length or
customized length
6.4.3
FUSING
The correction factor of a fuse shall be determined by an authorized professional electrical engineer
in accordance with the relevant design regulations and system simulation results. Trina Solar does
not responsible for determining the minimum rating of fuse.
The fuse rated current should be chosen depending on different standards, as follows
1.5
𝐾
𝑓
⋅ 𝐼
𝑆𝐶
≤ 𝐼
𝑛
≤ 𝑀𝑎𝑥 𝑆𝑒𝑟𝑖𝑒𝑠 𝐹𝑢𝑠𝑒 𝑅𝑎𝑡𝑖𝑛𝑔 (𝐼𝐸𝐶 𝑠𝑡𝑎𝑛𝑑𝑎𝑟𝑑)
1.56
𝐾
𝑓
⋅ 𝐼
𝑆𝐶
≤ 𝐼
𝑛
≤ 𝑀𝑎𝑥 𝑆𝑒𝑟𝑖𝑒𝑠 𝐹𝑢𝑠𝑒 𝑅𝑎𝑡𝑖𝑛𝑔 (𝑁𝐸𝐶 𝑠𝑡𝑎𝑛𝑑𝑎𝑟𝑑)
where
𝐼
𝑛
Fuse rated current [A]
𝐼
𝑆𝐶
Short circuit current of the module [A]
𝐾
𝑓
Temperature correction factor [-]
A correction factor (
𝐾
𝑓
) should be applied for determining the fuse rated current working at different
temperatures. Please confirm the final fuse selection with the qualified design institutes and fuse
manufacturer. The
maximum series fuse rating value on the products’ datasheet provided by Trina
Solar should be used for reference only.
(Linear Wiring)