Tweed 240V HI CAPACITY Power Transformer Connection Schematic
Connect a Black/Hot
line from the IEC Line
lug to the fuse holder.
Run a wire from the lug
on the side of the fuse
holder and from the
end of the holder to the
power switch. Make
sure the switch is in the
desired on position, the
connection is ‘made’.
The switch may have
the option of being
‘On’ in either ‘Up’ or
‘Down’ position. From
the other side of the
switch, connect to the
transformer Black/Red
lead (240V input).
The other side of the
IEC is connected to the
White lead (‘Common’
side) of the power
transformer.
Connect the Black and
White/Red, solder and
insulate with some
shrink tubing.
Tie off the unused taps
(110V) that are not
required for the Tweed
build. Tie it off by
cutting off the exposed
wire and then put heat-
shrink over the end and
then tuck it away as it is
not used.