www.energyabsorption.com
Revision A May 2013
www.highwayguardrail.com
7
All rights in copyright reserved
Operation
1. Unlock the gate (see Figure 1 & 2).
Open the manual jack access cover located at the middle of the gate and remove the handle
attached to it. Remove the safety retaining pin from the rear of the manual jack support. Insert
the handle onto the jack nut and crank the jack all the way to unlock the gate. (Turn clockwise.)
2. Crank the gates open (see Figure 3).
Open the manual drive cover on the capstan drive enclosure, release the catch on the lid, and
lay the lid back. Remove the guard on the manual drive crank. Insert the manual jack handle
onto the low speed (outermost) drive shaft and crank the gates open. The high speed
(innermost) drive shaft can be used when the gate is opened 3 m [10’] or more.
3. Reverse order to close and lock gate.
Caution:
The weight of the gate may cause the Manual Crank Handle to want
to spin. Hold the handle tightly to maintain control. Low speed operation is
recommended at first until operator becomes familiar with gate manual operation.
Figure 1
Unlock Gate
Figure 2
Figure 3
Crank Open